![Siemens Nespresso TK911 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/siemens/nespresso-tk911/nespresso-tk911_repair-instructions_375834028.webp)
5.3 Descaling
cycle
Running the descaling programme
User action
Appliance response
1.
Select Descaling menu option
Empty drip trays and capsule container, press steam button
2.
DISPLAY
Empty container and press Steam button
3.
Spindle motor
moves up to 2 mm in front of brewing position
Pour in descaling solution, press Steam button
DISPLAY
Fill with agent + water and press steam button
4.
Check point: Agent in tank? (Via flowmeter)
Descaling solution via steam pipe, drip tray and coffee outlet
DISPLAY
Descaling is running
5.
Cooling down:
Pump ON until heater has cooled down to 70 °C. Discharge into drip tray
Descaling solution via steam pipe:
Solenoid valve on, up to 100 ml have run through
Pump OFF for 30 seconds, 20 ml flow (repeat 10 x)
Pump OFF, close solenoid valve
Descaling solution via drip tray
Solenoid valve on, up to 100 ml have run through. Discharge into drip tray
Descaling solution via coffee outlet
50 ml flow
Pump OFF for 30 seconds, 20 ml flow (repeat until tank empty)
Empty drip trays and capsule container
DISPLAY
Empty container
6.
Check point: IR sensor trays
58300000116013_en_a – 21.08.06
Seite 28 von 61