Supported Software

Here is a list of software supporting the IP Router N 146.

ComBridge Studio

IPAS GmbH
Grabenstr 149 a
47057 Duisburg
Germany
[http://www.ipas-products.com]

Visualization, Database interface,
Notification via email, OPC Server

ComBridge Studio is a visualization software that can
use the IP Interface N148/22, the IP Router N146, the IP
Controller N350E and the IP Viewer N151 as interface to
KNX/EIB. Find more information in the GAMMA catalog
or at the above listed web site.

ETS 3

KNX Association

De Kleetlaan 5, Bus 11
B-1831 Brussels-Diegem

Belgium
[http://www.knx.org]

Configuration of bus installations via existing
data net works (ETS 3.0c or higher)

An KNXnet/IP driver is available for ETS3. When this
driver is installed ETS3 may use the IP Interface
N148/21, the IP Router N146, the IP Controller N350E
and the IP Viewer N151 as interfaces to the bus just like
a standard RS232 or USB serial interface. This function
includes download of device configuration via the bus
and the group monitor function of ETS3.

Note

The KNX Association has decided that IP routers shall
not implement support for busmonitoring.
The ETS3 driver currently does not support local
download.

Note

After installing the ETS3 driver and selecting the
IP Interface or the IP Router as communication interface
a windows message may pop up announcing that a
"Class" is unknown.
In this case install the Microsoft .Net Framework that you
can download from the Microsoft software update site
(file size: approx. 25MB).

General Notes

·

  The operating instructions must be handed over to the

client.

·

  Any faulty device is to be sent together with a return

delivery note of the local Siemens office.

·

  For any technical questions, please consult:

'

  +49 (911) 895-7222

7

  +49 (911) 895-7223

*

 [email protected]

www.siemens.com/automation/support-request

Содержание N146/02

Страница 1: ...rarchically superimposed systems via Internet Protocol IP Direct access to the KNX EIB installation from any access point to the IP network KNXnet IP Tunneling Fast communication between KNX EIB lines areas and systems KNXnet IP Routing Communication between buildings and facilities Filtering and routing of telegrams depending on individual address group address LED display of operation KNX EIB co...

Страница 2: ... 5 5 1 Figure 1 IP Router as area and line coupler EIBnet IP Router 1 0 0 IP Network EIBnet IP Router 2 0 0 Main Line 1 Main Line 2 Line Coupler 1 1 0 Line Coupler 1 2 0 Line Coupler 1 3 0 Line Coupler 2 1 0 Line Coupler 2 2 0 Device 1 1 1 Device 1 1 2 Device 1 2 1 Device 1 2 2 Device 1 3 1 Device 1 3 2 Device 2 1 1 Device 2 1 2 Device 2 2 1 Device 2 2 2 4 1 1 4 1 1 4 1 1 5 2 1 5 2 1 4 1 1 4 1 1 4...

Страница 3: ...e one or more of the additional individual addresses could be assigned twice When during normal operation the learning button is pressed for more than 10 seconds all additional individual addresses in the IP Router N146 02 are reset to the default value 15 15 255 and the programming LED is turned off IP address assignment The IP address of the IP Router N146 02 is assigned manually using ETS autom...

Страница 4: ...ay be used for permanent interior installations in dry locations within distribution boards or small casings with DIN rail EN 60715 TH35 7 5 V WARNING The device must be mounted and commissioned by an authorised electrician Free DIN rail areas with sticked in data rails must be covered with covers order no 5WG1 192 8AA01 The prevailing safety rules must be heeded The device must not be opened For ...

Страница 5: ...nd addressing mode Display elements 1 green LED device ready ON 1 yellow LED Communication on bus line 1 green LED Ethernet Link Signal available Lk 1 yellow LED Receiving data from Ethernet Rx 1 red LED Transmitting data to Ethernet Tx 1 red LED for monitoring bus voltage and displaying mode selected with the learning button Connections bus line screwless bus connection block red black 0 6 0 8 mm...

Страница 6: ...iption The N system DIN rail device can be installed in N system distribution boards surface or flush mounted or on any DIN rail complying with EN 60715 TH35 7 5 The connection to the bus line is established via the bus connector terminal red black on the top side The RJ45 socket on the device front side provides the connection to the Ethernet IP data network Mounting DIN rail devices Figure 5 Sli...

Страница 7: ...single core conductors Ø 0 6 0 8 mm Remove approx 5 mm of insulation from the conductor D2 4 and plug it into the bus connection block D2 red black Disconnecting bus cables Figure 6 Unplug the bus connection block E1 and remove the bus cable conductor E1 4 while simultaneously wiggling it D2 D D2 D2 4 5 mm D2 D2 4 D2 1 D2 2 D2 D2 3 Figure 6 Connecting and disconnecting bus wires Slipping off on au...

Страница 8: ... net works ETS 3 0c or higher An KNXnet IP driver is available for ETS3 When this driver is installed ETS3 may use the IP Interface N148 21 the IP Router N146 the IP Controller N350E and the IP Viewer N151 as interfaces to the bus just like a standard RS232 or USB serial interface This function includes download of device configuration via the bus and the group monitor function of ETS3 Note The KN...

Отзывы: