background image

8

Electrical connection

Before installation

Exhaust air towards the rear:

Pipe diameter: 100 mm

Take out the air-deflector Fig. 8/1.

Insert the exhaust-air connection
(Fig.8/3) 

Close top exit with supplied jerk
(Fig.8/3).

Circulating-air mode 

Fig. 9

(If there is no exhaust-air mode option)

The air purified by an additional
activated carbon filter is conveyed back
into the room.

For insertion of the activated carbon 
filter see Instructions for use.

If the extractor hood is switched from
exhaust-air mode to circulating-air
mode, the exhaust-air opening must be
sealed to prevent a hazardous situation.

Electrical specifications:

Electrical specifications can be found on
the rating plate – remove the filter frame
inside the appliance to reveal the rating
plate.

Before carrying out any repairs,

isolate the extractor hood.

Length of connection cable: 1,50 m.

To prevent a hazardous situation, a

damaged connection cable must be 
replaced by the manufacturer or his 
customer service or a similarly qualified
person.

If a permanent connection is required:

The extractor hood may be connected only
by an electrical engineer who is registered
at the relevant electricity supply company.

A disconnecting device must be fitted on
the installation side. Switches with a
contact gap of more than 3 mm and 
all-pole disconnection are regarded as a
disconnecting device. This includes LS
switches and contactors.

This extractor hood complies with the EC
radio interference suppression regulations.

Electrical connection

THIS APPLIANCE IS EARTH INSULATED,
DO CONNECTED TO EARTH.

-

If the supply cord of this appliance is

damaged, it must be replaced. Take
care to shock azard. Do never change
the fuse without rettifing the cover; if you
have lost the cover, do not use the plug
until the cover is replaced, call your dea-
ler for spare parts.

-  If the appliance is supplied with UK plug

(BS 1363) than it's protected by a 3A
fuse or if any other type of plug is used,
by a 5A fuse either in the plug or
adaptor or at the distribution board.

56080 Int  10-01-2003  11:00  Pagina 8

Содержание LU13 series

Страница 1: ...Operating Instructions Installation Instructions LU13 LU22 ...

Страница 2: ......

Страница 3: ...yed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If the extractor hood is switched from exhaust air mode to circulating air mode the exhaust air opening must be sealed to prevent a hazardous situation see optional accessories in the Instructions for use Important information This extractor hood ...

Страница 4: ...never be left unattended Do not flambé under the extractor hood Risk of grease filter catching fire catching fire from rising flames Certain restrictions apply if the extrac tor hood is to be installed over a fireplace which burns solid fuel coal wood etc see Installation instructions Always use gas hotplates correctly Important The flames of the gas hotplates must always be covered with a cooking...

Страница 5: ...s of the filter grille Fig 1 1 2 Remove the filter grille Fig 1 2 3 Remove the wire grille and the saturated filter mat Fig 2 4 Clean the filter grille and insert a new filter mat Fig 2 5 Clamp the filter mat with the wire grille Fig 2 6 Re insert the filter grille Fig 1 2 The interlocks must lock into position on the left and right sides Fig 1 1 Metal grease filter The filter mats consist of non ...

Страница 6: ... the filter grille Fig 1 1 2 Remove the filter grille Fig 1 2 3 Insert the activated carbon filter from below into the extractor hood housing and lock into position and turned clockwi se fig 3 4 Re insert the filter grille Fig 1 2 The interlocks must lock into position on the left and right sides Fig 1 1 Removing The activated carbon filter is removed in reverse sequence Replacing the activated ca...

Страница 7: ...tainless steel cleaning agent Stainless steel surfaces Use a mild non abrasive stainless steel cleaning agent Clean only in the direction of the ground surface Do not clean stainless steel surfaces with scouring sponges or with cleaning agents containing sand soda acid or chlorides Replacing the lamps 1 Switch off the extractor hood and isolate the extractor hood by pulling out the mains plug or s...

Страница 8: ...tinuous flow heaters water heaters ensure that the fireplace has an adequate air supply for combustion Before reading these instructions please fold out the illustrated back pages Important information Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old appliances Before disposing of your old appliance render it unusable You received your new appliance...

Страница 9: ...r mode with activated carbon filter there are no operating restrictions If the exhaust air is conveyed through the exterior wall a telescopic wall box should be used Fig 7 Connection options between the extractor hood and telescopic wall box Exhaust air hose or exhaust air pipe Direct connection Optimum performance of the extractor hood Short smooth exhaust air pipe Minimum number of pipe bends La...

Страница 10: ...on cable must be replaced by the manufacturer or his customer service or a similarly qualified person If a permanent connection is required The extractor hood may be connected only by an electrical engineer who is registered at the relevant electricity supply company A disconnecting device must be fitted on the installation side Switches with a contact gap of more than 3 mm and all pole disconnect...

Страница 11: ...erfect hori zontal level fig 11 1 adjust it by using the adjusting screws fig 11 2 7 Tighten the lower screw with washer inside the extractor hood Fig 12 To a wall hanging cupboard 60 cm wide extractor hood With 4 screws Fig 13 90 cm wide extractor hood With 4 screws Fig 13 1 Dimensions for the mounting boreholes can be found in Fig 13 or place a tem plate on the base of the wall hanging cupboard ...

Страница 12: ...10 Notice ...

Страница 13: ...11 Notice ...

Страница 14: ...12 Notice ...

Страница 15: ......

Страница 16: ......

Страница 17: ...Installation Instructions ...

Страница 18: ......

Страница 19: ......

Страница 20: ...LIB0024982B Ed 07 15 BSH Ev Aletleri Sanayi ve Ticaret A Ş FSM Mah Balkan Cad 51 34771 Ümraniye İstanbul TURKEY www siemens home com ...

Отзывы: