background image

4

Cleaning and care

Risk of burns, risk of electric shock!

from appliance. Always leave appliance to cool down before 
cleaning or servicing. Switch off fuse or pull out mains plug.

Caution!

Risk of damage due to ingress of humidity into the electronic 

circuitry. Never clean operator controls with a wet cloth.

Surface damage due to incorrect cleaning. Clean stainless 

steel surfaces in the grain direction only. Do not use any 

stainless steel cleaners for operator controls.

Surface damage due to strong or abrasive cleaning agents. 

Never use strong and abrasive cleaning agents.

Maintenance and repair

Risk of fire, risk of injury!

from improper repairs. Switch off the fuse or pull out the mains 
plug. Repairs may be performed by a qualified technician 
(electrician) only.

Risk of injury!

from a defective or damaged appliance. Switch off the fuse or 
pull out the mains plug and call customer service.

Risk of fire, risk of injury!

from damaged connection cable. A damaged connection cable 
must be replaced by a qualified technician (electrician).

Risk of burns, risk of electric shock!

from defective bulbs. Switch off the fuse or pull out the mains 
plug. Always replace defective bulbs immediately (leave bulbs 
to cool down first) to prevent the remaining bulbs from 
overloading. 

Operating modes

This appliance can be used in exhaust-air mode or circulating-

air mode.

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a functioning 

smoke or exhaust gas flue or into a shaft which is used to 

ventilate installation rooms which contain heating appliances.

Before conveying the exhaust air into a non-functioning 

smoke or exhaust gas flue, obtain the consent of the heating 

engineer responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Circulating-air mode

Note: 

To bind odours in circulating-air mode, you must install 

an activated carbon filter. The different options for operating the 

appliance in circulating-air mode can be found in the brochure. 

Alternatively, ask your dealer. The required accessories are 

available from specialist outlets, from customer service or from 

the Online Shop. The accessory numbers can be found at the 

end of the instructions for use.

Operation

These instructions apply to several appliance variants. It is 

possible that individual features are described which do not 

apply to your appliance.

Note: 

Switch on the extractor hood when you start cooking and 

switch it off again several minutes after you have finished 

cooking. This is the most effective way of removing the kitchen 

fumes.

Control panel variant 1

The air which is drawn in is cleaned by the 

grease filters and conveyed to the exterior by a 

pipe system.

The air which is drawn in is cleaned by the 

grease filters and an activated carbon filter and 

conveyed back into the kitchen.

/LJKW

2Q2II

2Q2II

'LVSOD\

)DQVHWWLQJV

6ZLWFKIDQ

VHWWLQJGRZQ

6ZLWFKIDQVHWWLQJXS
,QWHQVLYHVHWWLQJ

Содержание LC98BC540

Страница 1: ... HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH WUDFWRU KRRG ...

Страница 2: ...r is not liable for damage which is caused by improper use or incorrect operation Danger of suffocation from packaging material Never allow children to play with packaging material After unpacking the appliance check it for visible damage Do not connect the appliance if it has been damaged in transit These instructions apply to several appliance variants It is possible that individual features are...

Страница 3: ...rve the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Risk of electric shock from damaged connection c...

Страница 4: ... air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heating appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through the outer wall a telescopic wall...

Страница 5: ...hock from appliance Always leave appliance to cool down before cleaning or servicing Switch off fuse or pull out mains plug Removing metal mesh grease filter 1 Open the lock and fold down the metal mesh grease filter While doing this place the other hand under the metal mesh grease filter 2 Take the metal mesh grease filter out of the holder With edge extraction 1 Pull metal mesh grease filter dow...

Страница 6: ...e metal mesh grease filters can be cleaned in the dishwasher or by hand In the dishwasher Note If the metal mesh grease filters are cleaned in the dishwasher slight discolouration may occur This has no effect on the function of the metal mesh grease filters Do not clean heavily soiled metal mesh grease filters together with utensils Place the metal mesh grease filters loosely in the dishwasher The...

Страница 7: ...lways be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exha...

Страница 8: ...13 cm2 Flat ducts should have no sharp deflections Use sealing strip for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structure...

Страница 9: ...hen attaching the appliance ensure that it engages firmly with the brackets 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left Securing the appliance 1 Press the safety caps with the arrow upwards onto the brackets until they engage 2 Screw on the knurled nut and washer firmly Removing the safety caps If the safety caps must be re...

Страница 10: ...ocket should be connected via its own circuit If the earthed socket is no longer accessible following installation of the appliance a disconnecter must be fitted as for a permanent connection If a permanent connection is required the installation must feature an all pole disconnecter circuit breakers fuses and contactors with a min 3 mm contact opening The permanent connection may be installed by ...

Страница 11: ...11 ...

Страница 12: ...Siemens Electrogeräte GmbH Carl Wery Straße 34 81739 München Germany 9000548221 9000548221 930903 ...

Отзывы: