en
33
Fault
Possible cause
Remedial action
The temperature in
the refrigerator
compartment is too
cold.
A colder temperature
in the freezer
compartment can also
lower the temperature
in the refrigerator
compartment. This is
quite normal.
Set the temperature in
the refrigerator compartment slightly
warmer.
Should this not be enough, e.g. if the
room temperature is too low, set the
freezer temperature warmer.
Displays
do not illuminate.
Power failure; the fuse
has been switched off;
the mains plug
has not been inserted
properly.
Connect mains plug. Check whether
the power is on, check the fuses.
The temperature in
the freezer
compartment is too
warm.
Appliance opened
frequently.
Do not open the appliance
unnecessarily.
The ventilation
openings have been
covered.
Remove obstacles.
Large quantities of
fresh food are being
frozen.
Do not exceed max. freezing
capacity.
Freezer compartment
door was open
for a long time;
temperature is no
longer reached.
The evaporator
(refrigeration
generator)
in the No Frost system
is covered in thick ice
and can no
longer be defrosted
fully automatically.
To defrost the evaporator, remove
the frozen food
with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move
it away from the wall. Leave
the appliance door open.
After approx. 20 min.
the condensation begins to run
into the evaporation pan,
at the rear of the appliance. Fig.
8
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation
with a sponge.
The evaporator is defrosted when
the water stops running
into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
Содержание KDN Series
Страница 87: ...1 max 22 20 18 16 6 7 8 9 10 11 12 13 17 16 15 14 5 4 2 1 3 max 22 20 18 16 ...
Страница 88: ...2 3 4 5 6 7 ice box ...
Страница 89: ...8 9 ...
Страница 90: ... A ...
Страница 91: ... B ...
Страница 92: ...Siemens Electrogeräte GmbH Carl Wery Str 34 81739 München Germany 9000319706 9000319706 de en fr it nl 9112 ...