16
Operating manual Pocket ISDN-TA
ATI7
Returns
“OK“
ATI8
Returns
“ERROR”
ATI9 Returns plug and play ID string
ATI77 Returns Bootloader version string
ATI99 Returns software creation date
&K
Flowcontrol
Selects the flow control behavior of the POCKET ISDN-TA while in data
communication phase.
AT&K No local flow control between the DTE and TA is used
AT&K3
Local flow control is set to hardware handshake RTS/CTS (default)
AT&K4 Local flow control is set to software handshake XON/XOFF
#M
Received CLID
Shows the called line identification (CLID) that is received with an incoming call –
this is the number of the called party addressed on the local S-bus (selected msn).
AT#M
N
Set line baudrate V.110
Selects the line baudrate of the POCKET ISDN-TA to the desired value (only valid for
B channel protocol V.110 asynchronous).
ATN0 Line baudrate automatic set (equals to local baudrate or less)
ATN1 Line baudrate set to 1200 bit/s
ATN2 Line baudrate set to 2400 bit/s
ATN3 Line baudrate set to 4800 bit/s
ATN4 Line baudrate set to 9600 bit/s
ATN5
Line baudrate set to 19200 bit/s