Replacing the seal of the compartment cover
SIMATIC IPC277D/E 19" INOX PRO, SIMATIC IFP1900 INOX PRO
8
Service Manual, 11/2017, A5E35751762-AC
1.
Remove the six screws of the terminal compartment cover.
2.
Remove the terminal compartment cover.
CAUTION
Do not drop the terminal compartment cover
Dropping the terminal compartment cover may result in minor injuries or damages to the
device.
Prevent the terminal compartment cover from dropping, especially when it is mounted
on a stand or support arm.
3.
Remove the seal of the terminal compartment cover.
4.
Insert the spare seal as shown in the figure.
5.
Check the seal for correct seat; make sure that the bore holes of the seal enclose the
collar of the press-fit components, see marked locations.
6.
Place the terminal compartment cover on the terminal compartment and reinsert the
six screws.
7.
Tighten all six screws with a torque of 3.5 Nm.