Commissioning
3.5 Transducer Installation
SITRANS FUH1010 Quick Start
Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
29
①
Optional: On larger pipes, multiple lengths of straps
can be linked together to surround pipe
⑤
Space Bar Platform &
Clamping Screw
②
Mounting Strap positioned around Mounting Frame
⑥
Space Bar (Front View)
③
Transducer shown in the 9 o'clock position on pipe
⑦
Metal Post
④
Mounting Frame
⑧
Mounting Strap Adjusting
Screw
Figure 3-5
Reflect Mount with Mounting Frame and Spacer Bar
Installation Procedure (See figure 3-7 for reference)
1.
On a flat surface, attach the Spacer Bar to a Mounting Frame so that the Reference Hole
on the Spacer Bar fits over the metal post on the platform of the frame. Tighten the
securing screw.
2.
Slide the second Mounting Frame onto the other end of the Spacer Bar and align the
Number Index Hole with the metal post on the platform. Then tighten the clamping screw.
Ensure that the angled sides of both frames face away from each other.
3.
Wrap a Mounting Strap around the pipe. Make sure to position it so there is easy access
to the mounting strap adjusting screw.
4.
At the mounting location, place the Mounting Frame/Spacer Bar Assembly on the pipe so
that it rests on the top of the pipe.
5.
Engage the end of the Mounting Strap with the Mounting Strap Adjusting Screw.
6.
Slide Mounting Strap under the spring clip of one of the Mounting Frames.
7.
Tighten the Mounting Strap Screw enough to take up all of the slack, but not enough to
prevent rotation of the assembly.
Repeat procedure for the other Mounting Frame.
8.
Rotate the assembly on the pipe to the final conditioned location, ensuring that it is
straight along the pipe axis. (Refer to the transducer orientation diagram in Figure 3-7.)
9.
Tighten the Mounting Straps to seat the assembly firmly on the pipe. Do not over tighten.
Содержание FUH1010 IP65 NEMA 7 Compact
Страница 2: ......
Страница 14: ......
Страница 18: ......
Страница 36: ......
Страница 40: ......
Страница 46: ......
Страница 60: ......
Страница 64: ......
Страница 106: ......
Страница 110: ......
Страница 132: ......
Страница 152: ......
Страница 156: ......
Страница 178: ......
Страница 187: ......