Outline and Dimensions
Mounting
•
Mount the transducer so that it is above the maximum material level by at least the
blanking value. Refer to the associated controller manual.
•
On liquid applications, mount the transducer face parallel to the liquid surface. On solids
applications, use a Siemens Milltronics Easy Aimer to help aim the transducer.
•
Do not overtighten. Most applications require only hand tightening of the mounting
hardware. Connect a safety chain from the transducer to a structural member to secure
installation. Consider using the optional temperature sensor when a flanged transducer
is used, when a fast temperature response is required, or in high temperature vessels.
Dimension
XPS-10
XPS-15
XPS-30
XPS-40
XCT-8
XCT-12
A
88 mm (3.4") 121 mm (4.8") 175 mm (6.9") 206 mm (8.1") 88 mm (3.4") 121 mm (4.8")
B
122 mm (4.8") 132 mm (5.2") 198 mm (7.8") 229 mm (9.0") 122 mm (4.8") 132 mm (5.2")
C
to suit ANSI, DIN and JIS standards
D*
128 mm (5.0") 138 mm (5.4") 204 mm (8.0") 235 mm (9.2") 128 mm (5.0") 138 mm (5.4")
E
124 mm (4.9") 158 mm (6.2") n / a
n / a
n / a
n / a
F
152 mm (6.0") 198 mm (7.8") n / a
n / a
n / a
n / a
G
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
* nominal
WARNING:
Optional Split Flange, Bonded Flange, and Easy Aimer configurations
are not suitable for pressure applications.
WARNING: Special handling precautions must be taken to protect the
face of the transducer from any damage.
Note:
For pressure tight applications, install transducers hand tight plus ½ turn to 1½
turns. PTFE tape or other appropriate sealant may be used to aid in sealing the threads for
use in pressure applications.
B
A
C
B
F
E
C
D
G
standard
radiating
face
optional bonded flange
refer to associated instructions
optional split flange
refer to associated instructions
optional
submergence shield
refer to associated
instructions
Содержание Echomax XCT Series
Страница 1: ...Operation Manual February 2005 ECHOMAX xps xct ...
Страница 2: ......
Страница 12: ...Page EN 10 XPS XCT Series Transducers OPERATION MANUAL 7ML19985QM82 English ...
Страница 22: ...Side DA 10 XPS XCT Serie Transducere DRIFTSVEJLEDNING 7ML19985QM82 Dansk ...
Страница 32: ...Seite DE 10 Ultraschallsensoren XPS XCT BETRIEBSANLEITUNG 7ML19985QM82 Deutsch ...
Страница 42: ...Σελίδα EL 10 Μορφοτροπείς σειρών XPS XCT ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ 7ML19985QM82 Ελληνικά ...
Страница 52: ...Página ES 10 Sensores XPS XCT MANUAL DE OPERACIÓN 7ML19985QM82 Español ...
Страница 62: ...Page FR 10 Transducteurs Série XPS XCT MANUEL D UTILISATION 7ML19985QM82 Français ...
Страница 72: ...Pagina IT 10 Trasduttori serie XPS XCT MANUALE OPERATIVO 7ML19985QM82 Italiano ...
Страница 82: ...Pagina NE 10 XPS XCT serie transducers BEDIENINGSHANDLEIDING 7ML19985QM82 Nederlands ...
Страница 92: ...Página PT 10 Transdutores Séries XPS XCT MANUAL DE FUNCIONAMENTO 7ML19985QM82 Português ...
Страница 102: ...sivu SU 10 XPS XCT sarjan anturit KÄYTTÖOPAS 7ML19985QM82 Suomi ...
Страница 112: ...Sida SV 10 XPS XCT Transducerserier ANVÄNDNINGSMANUAL 7ML19985QM82 Svenska ...