Siemens Schweiz AG 

 

A6V11937668_en--_b 

Smart Infrastructure 

 

2020-07-10 

●  Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected. 

●  Consult the dealer or an experienced radio/TV technician for help. 
This device complies with Part 15 of the FCC rules. Operation is subject to the following two 
conditions:  

1.  This device may not cause harmful interference, and  

2.  this device must accept any interference received, including interference that may cause 

undesired operation 

FCC Caution:

 Changes or modifications not expressly approved by Siemens Switzerland 

Ltd. could void the user’s authority to operate the equipment. United States representative  

https://new.siemens.com/us/en/products/buildingtechnologies/home.html

 

Industry Canada statement 

This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following 
two conditions: 

1.  This device may not cause interference, and 

2.  this device must accept any interference received, including interference that may cause 

undesired operation. 

Radio frequency radiation exposure Information for USA and Canada 

This equipment complies with FCC and IC radiation exposure limits set forth for an 
uncontrolled environment.  
This equipment should be installed and operated with a minimum distance of 20 cm (8 in) 
between the radiator and your body.  
This transmitter must not be co-located or operated in conjunction with any other antenna or 
transmitter. 

  

Housing 

 

Color top/bottom 

RAL 7035 (light grey) / RAL 7016 (anthracite grey) 

Dimensions 

per DIN 43880, see dimensions 

Weight without/with packaging 

484 g / 554 g 

 

 

  

Connection terminals 

65 66 67

68 69 70

3

4

5

6

7

8

9

    

 

 

Terminal

 

Symbol

 

Description

 

Module

 

Channel

 

3, 4 

KNX 

KNX PL-Link (for future use) 

 

 

5, 6 

24 V ~, 

 

Operating voltage AC 24 V 

 

 

 

Functional ground (must be connected on the installation side 
with the building grounding system (PE). 

 

 

8 to 29 

Ux 

Universal inputs/outputs 

61 

1…12 

 

 

Measuring ground for Ux 

 

 

Содержание Desigo PXC4.M16

Страница 1: ...freely programmable using graphical programming interface Communication BACnet MS TP 16 inputs outputs 12 universal inputs outputs 4 relay outputs Extendable to 40 inputs outputs via I O modules TXM Integration of Modbus data points via RTU WLAN interface for engineering and commissioning Operating voltage AC 24 V Mounted on standard rails or on the wall Plug in screw terminal blocks ...

Страница 2: ...y outputs DO 4 Number of inputs outputs Onboard TXM 40 Number of Modbus data points RTU 40 UIO Universal inputs outputs support the following signal types Passive sensors LG Ni 1000 2x LG Ni1000 Pt 1000 75 385 NTC 10k NTC 100k Resistance sensors 1000 Ohm 2500 Ohm 2650 Ohm 1000 1175 Ohm for setpoint shift Active sensors DC 0 10 V Current measurement analog DC 0 20 mA or 4 20 mA inputs U1 U2 U7 U8 B...

Страница 3: ...itch for bus termination and polarization COM MS TP 12 Slider for mounting on DIN rails 13 Eyelets for cable ties 1 Plastic housing 14 Holes for wall mounting 2 Service button identification in network and WLAN on off 15 Date Series and Serial number 3 LEDs for communication and state 16 QR code for default WLAN access description see Technical data LED displays Activity LED Color Activity Functio...

Страница 4: ...al declarations CE declarations etc can be downloaded from the following Internet address https siemens com bt download Notes Safety CAUTION National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage Observe national provisions and comply with the appropriate safety regulations This equipment is intended only for use in a restri...

Страница 5: ...ers or install the device in a lockable cabinet Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage Dispose of the device through channels provided for this purpose Comply with all local and currently applicable laws and regulations Technical data Power supply Operating voltage 24 V AC 24 V 15...

Страница 6: ... 1 0 mm2 22 to 18 AWG Cu strand without wire end sleeve 1 x 0 6 mm to 2 5 mm2 22 to 14 AWG or 2 x 0 6 mm to 1 5 mm2 22 to 16 AWG Stripping length 6 7 5 mm 0 24 0 29 in Screwdriver Slot screws screwdriver size 1 Max tightening torque 0 6 Nm 0 44 lb ft BACnet MS TP interface Interface type EIA 485 electrically isolated Baud rate 9600 19200 38400 57600 76800 115200 depending on the configuration Inte...

Страница 7: ...LAN client is connected Optionally for cyber security reasons the WLAN can be permanently disabled via configuration Default SSID and WLAN password Scan the QR code It will show something like WIFI S PXC4 M16_0000550 T WPA P 1400052738 Then SSID PXC4 M16_0000550 and password 1400052738 Determine manually Use the information from the Date Series SN block It will show something like Date Series 2019...

Страница 8: ...175 Ω 900 1295 Ω 0 1 Ω A fixed value of 1 Ω is calibrated to correct line resistance Voltage measurement analog Type Range over range Resolution AI 0 10 V 0 10 V 1 5 11 5 V 1 mV AI 0 10 V standard 0 100 10 110 0 01 Open connection Negative voltage 1 5 V line failure detection Current measurement analog only inputs U1 U2 U7 U8 Type Range over range Resolution Load AI 4 20 mA 4 20 mA 1 6 22 4 mA 1 µ...

Страница 9: ...t Max 3 A resistive at DC 30 V NC contact Max 1 A resistive at DC 30 V Min 10 mA resistive at DC 12 V Switch on current NO contact Max 10 A 1 s NC contact Max 3 A 1 s Response release time 7 ms 3 ms typical Contact life at AC 250 V reference values At 0 3 A resistive NO contact at 3 A resistive NC contact at 2 A resistive Reduction fact at ind load cos phi 0 6 5 x 105 switchings 1 x 105 switchings...

Страница 10: ...L approbation US Canada UL916 http ul com database CSA certification C22 2 http csagroup org services industries product listing FCC CFR 47 Part 15 Class B BACnet B BC Environmental compatibility 1 The product environmental declaration 1 contains data on environmentally compatible product design and assessments RoHS compliance materials composition packaging environmental benefit disposal 1 Docume...

Страница 11: ...lowing two conditions 1 This device may not cause interference and 2 this device must accept any interference received including interference that may cause undesired operation Radio frequency radiation exposure Information for USA and Canada This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated w...

Страница 12: ...erface EIA 485 BACnet MS TP 68 69 70 COM Interface EIA 485 Modbus RTU Term on off Switch for bus connection Polar on off Switch for polarization 75 to 86 DOx Relay outputs 11 1 4 Wiring lines for field devices Wiring length max 300 m 1 000 ft CU wire or CU strand Cross section depending on the signal 30 m 100 ft applies for signal types AI NTC10K and AI NTC100K or 80 m 260 ft with shielding ...

Страница 13: ... general Resistance transmitter Active sensor powered by the automation station Active sensor with external power Do NOT ground external power ground loops Active sensors 0 20 mA or 4 20 mA 2 wire On U1 U2 U7 U8 only Analog outputs Ux Ux V Ux V V Y1 Y2 Y3 Device with input DC 0 10 V General device with control input DC 0 10 V Powered by the automation station General device with control input DC 0...

Страница 14: ...om buildingtechnologies Siemens Switzerland Ltd 2020 Technical specifications and availability subject to change without notice Document ID A6V11937668_en _b Edition 2020 07 10 Dimensions All dimensions in mm and inches PXC4 M16 183 7 20 198 7 80 117 41 61 124 4 88 4 1 0 16 70 5 2 78 49 1 91 26 5 1 04 45 1 77 67 2 64 110 4 33 3 0 12 7 0 28 PXC4 M16 with I O modules TXM 198 7 80 64 2 52 64 2 52 90 ...