S p e c i f i c a t i o n s
* Plus any pressure loss at the tap mixer
Special accessories
■
BZ 45U20 Pipe set: When using the continuous-flow
heater as a built-under appliance.
■
Priority switch (load reducing relay) BZ 45L20:
For operation with the priority circuit.
■
BZ 45K22 Mounting set: For surface-mount installation.
Rated power
[kW]
18
21
24
27
Rated voltage
380 – 415 V
380 – 415 V
380 – 415 V
400 V3~
Warm Water Quantity at Rated Power
for temperature increases of:
12 °C to 38 °C
[l/min]
9.9
11.6
13.2
13.9
12 °C to 60 °C
[l/min]
5.4
6.3
7.2
7.6
Switch-on quantity
[l/min]
2.6
2.6
2.6
2.6
Switch-on flow pressure*
[MPa (bar)]
0.025 (0.25)
0.025 (0.25)
0.025 (0.25)
0.025 (0.25)
Flow pressure
(at rated power and 60 °C)*
With flow limiter
[MPa (bar)]
0.028 (0.28)
0.035 (0.35)
0.048 (0.48)
0.064 (0.64)
Without flow limiter
[MPa (bar)]
0.013 (0,13)
0.020 (0,20)
0.026 (0,26)
0.035 (0,35)
Operative range in waters of
specific electric resistance at 15 °C
[
Ω
cm]
≥
1300
≥
1300
≥
1300
≥
1300
Rated pressure
[MPa (bar)]
1 (10)
1 (10)
1 (10)
1 (10)
Maximum permissible
supply temperature
[°C]
35
35
35
35
Maximum mains impedance
at connection site
[
Ω
]
–
≤
0,44
≤
0,36
≤
0,33
G
1 2
A
472
122
135
231
20
100
332
42
388
GB