Displays and operator controls
4.2 Mode selector
CP 342-5 / CP 342-5 FO
Manual, 10/2011, C79000-G8976-C146-09
21
4.2
Mode selector
Controlling the mode
There are different ways in which you can control the mode of the CP 342-5/342-5 FO, as
follows:
●
Mode selector
●
STEP 7 configuration software:
–
SIMATIC Manager / menu command: PLC > Display Accessible Nodes
–
NetPro / menu command: PLC > Operating Mode...
–
HW Config / menu command: PLC > Operating Mode...
–
NCM Diagnostics / menu command: Operating Mode
To control the CP mode from STEP 7, the mode selector must be set to RUN.
Mode selector
With the mode selector, you can set the following modes:
●
Change from STOP to RUN:
The CP enters the configured and/or loaded data in the work memory. The CP then
changes to STOP.
Diagnostics of the CP is possible.
●
Change from RUN to STOP:
The CP changes to STOP with the following response
–
Established connections (FDL and S7 connections) are terminated.
–
Configuration and diagnostics of the CP are possible
–
The following applies to DP mode:
- DP slave mode: the CP is no longer in data transfer
- DP master mode: the mode is "OFFLINE".
NOTICE
Longer transition times in complex systems
Depending on the extent of the configuration, it can take up to 1 minute before the
CP reaches the "OFFLINE" mode.
Further information
Read the explanations relating to the topic of "Downloading the configuration to the target
system" in the /1/ (Page 47) manual.
Содержание CP 342-5
Страница 6: ...Product overview and notes CP 342 5 CP 342 5 FO 6 Manual 10 2011 C79000 G8976 C146 09 ...
Страница 14: ...Requirements for use 2 3 Programming CP 342 5 CP 342 5 FO 14 Manual 10 2011 C79000 G8976 C146 09 ...
Страница 22: ...Displays and operator controls 4 2 Mode selector CP 342 5 CP 342 5 FO 22 Manual 10 2011 C79000 G8976 C146 09 ...
Страница 50: ...References B 3 On programming CP 342 5 CP 342 5 FO 50 Manual 10 2011 C79000 G8976 C146 09 ...