Condensed Operating Manual for Door Control Unit AT8

in the bottom right corner of the display.

6.   With a short pressing of the red parameter button (S5000) one can switch to parameter “A” 

(counterweight). The alternatively displayed numerical value represents the counterweight in kg 
(adjustment range 0 kg to 6 kg). It can be adjusted with the service button – 

“OPEN” 

and – 

“CLOSE”

 

(S500, or S500).

7.   The set value is saved by a long pressing of (>s) of the parameter button (S5000).
8.   Exiting the minimal editor takes place by switching the power supply off and on again.

NOTICE

 

An entry in the “C” parameter menu (profile selection) always overwrite the set value in the “A” 

parameter menu. Therefore, set the counterweight last.

WARNING

So that the closing and nudge speed can be limited dependent on the door weight, it is imperative 

that a new teach-in drive must be performed after taking over another movement profile (start with 

button S5000).

6   Relay contacts (option)

The relay contacts of the optional relay module can be set to relay the following door statuses to the 
elevator control of higher ranking order:

X (Pin and Pin3 closed)  

–   door has reached “CLOSE” position.

X (Pin and Pin3 closed)  

–   door reversed due to a blocking.

 

  Interruption of light barrier or opening demand.

X3 (Pin and Pin3 closed)  

–   door has reached “OPEN” position.

In illustration  the contacts are shown in an inactive status (Pin and Pin3 closed).

WARNING

It is imperative that the instructions in the operating manual are followed when the current >4V is 
connected to the relay module.

Содержание AG AT18

Страница 1: ... Condensed Operating Manual for Door Control Unit AT18 Rev 09 Issue Date 8 2007 www siemens de edm SIDOOR Condensed Operating Manual AT18 ...

Страница 2: ...dge Close Open X7 Motor plug X8 Connection for user terminal and USB adapter AT Frontend PC H5000 7 segment display for door status and error code S5000 Door parameter button S5001 Service button OPEN S5002 Service button CLOSE Relay module Option X11 Relay output CLOSE X12 Relay output Reversed X13 Relay output OPEN X14 Flat cable connection to the control unit Terminal module Option X15 Flat cab...

Страница 3: ...tion 2 Open housing lid 3 Plug in motor plug X7 4 Connect mains current transformer to mains 230 V AC The onsite fuse protection should be a maximum of 10A 5 Press red DOOR PARAM button S5000 and keep pushed in 6 Connect mains current transformer with X3 7 Press red DOOR PARAM button so long until the 7 segment display H5000 displays _ 8 After a short pressing of the OPEN S5001 button or the CLOSE...

Страница 4: ...in attachment 11 of the operating instructions Simple settings can also be executed with the three buttons and the 7 segment display of the basic equipment see section 5 WARNING The service staff should test the acceptable energies and forces after the putting into operation of the elevator door on the heaviest door in the complete system elevator and to adjust it to the critical limits in case of...

Страница 5: ...u Therefore set the counterweight last WARNING So that the closing and nudge speed can be limited dependent on the door weight it is imperative that a new teach in drive must be performed after taking over another movement profile start with button S5000 6 Relay contacts option The relay contacts of the optional relay module can be set to relay the following door statuses to the elevator control o...

Страница 6: ...of an adjusted parameter always takes place in the door position CLOSE Menu of the HT18 ESC Jump to RESET SIEMENS AT18 USER TERMINAL LANGUAGE MENU German LANGUAGE MENU English MAIN MENU Total alignment MAIN MENU Quick alignment MAIN MENU Monitor MAIN MENU Service SERVICE MENU FW version SERVICE MENU Fault Status SERVICE MENU Maintenance SERVICE MENU Special MONITOR MENU Door status MONITOR MENU In...

Страница 7: ... Condensed Operating Manual for Door Control Unit AT18 ...

Страница 8: ...0 6 13 Acil durumda akým beslemesi opsiyonel 11 6 14 Aþýrý yük emniyeti 11 7 Mekanik montaj ve ayarlar 12 8 Elektriksel ayarlar ve kullanýma alým 13 9 Röle temaslar Opsiyon 16 10 Hareket eðrisi 18 11 Çalýþma konumu göstergesi 19 12 Hýz sýnýr eðrisi 20 13 Geliþim modülü Opsiyon 21 13 1 Geliþtirme modüllerinin montajý 21 13 2 Acil akým modülü 25 13 2 1 AT18 ile acil durum modülünün baðlantýsý 25 14 ...

Отзывы: