Condensed Operating Manual for Door Control Unit AT8

2   Safety instructions

WARNING

Only 

qualified personnel

 should work on or be in the vicinity of this equipment.

This staff must be thoroughly familiarized with all warnings and maintenance procedures according to 
the operating manual.

3   Mechanical installation and configuration

.   Mount the motor on the motor mounting (rubber-bonded metal/vibration shock mount). 

Thereafter the motor is mounted on the mounting bracket if necessary.

.   Mount the overhead pulley, if necessary with mounting bracket. Make sure of the alignment of 

the drive pinion and the overhead pulley; these should be aligned with each other as precisely as 
possible.

3.   Bolt the timing belt and the door clutch holder together and set it up.
4.   Tighten the timing belt with the aid of the tensioning equipment. The correct tension is achieved 

when the timing belt can be pushed in by cm per every meter distance between the drive pinion 
and the overhead pulley.

5.   Mount the control unit close to the drive motor (take length of cable into account).

4   Initial electrical operation

.   Slide door to 

“CLOSE”

 position.

.   Open housing lid
3.   Plug in motor plug 

X7

4.   Connect mains current transformer to mains (30 V AC). The onsite fuse protection should be a 

maximum of 0A.

5.   Press red 

“DOOR PARAM”

 button (S5000) and keep pushed in.

6.   Connect mains current transformer with X3.
7.   Press red 

“DOOR PARAM”

 button so long until the 

7-segment display (H5000) displays “_”

.

8.   After a short pressing of the 

“OPEN” (S5001)

 button or the 

“CLOSE” button (S5002)

 the teach-in 

drive is started. The 

7-segment display (H5000)

 displays “H”.

 

The teach-in drive includes an opening of approximately 0 cm wide and closing once or twice at 
crawl speed.

 

Subsequently an opening and closing once over 5 cm in the crawl movement follows to 
determine the friction of the door system.

 

Thereafter the door opens and closes with reduced speed (complete trip). Herewith a short 
additional acceleration incline is passed through at the opening after an approximately 0 cm trip 
to determine the door weight.

 

The door parameter and the detected door width are stored in the 

“CLOSE”

 position.

 

The 

7-segment display (H5000)

 displays “u”.

9.   The door can now be opened with the 

“OPEN”

 button.

 

The 

7-segment display (H5000)

 displays “o” during the opening.

0.  Switch off control by pulling of the mains plug or of plug X3.
.  Connect control signals to plug X6 as in the terminal circuit diagram (see attachment 9).

Содержание AG AT18

Страница 1: ... Condensed Operating Manual for Door Control Unit AT18 Rev 09 Issue Date 8 2007 www siemens de edm SIDOOR Condensed Operating Manual AT18 ...

Страница 2: ...dge Close Open X7 Motor plug X8 Connection for user terminal and USB adapter AT Frontend PC H5000 7 segment display for door status and error code S5000 Door parameter button S5001 Service button OPEN S5002 Service button CLOSE Relay module Option X11 Relay output CLOSE X12 Relay output Reversed X13 Relay output OPEN X14 Flat cable connection to the control unit Terminal module Option X15 Flat cab...

Страница 3: ...tion 2 Open housing lid 3 Plug in motor plug X7 4 Connect mains current transformer to mains 230 V AC The onsite fuse protection should be a maximum of 10A 5 Press red DOOR PARAM button S5000 and keep pushed in 6 Connect mains current transformer with X3 7 Press red DOOR PARAM button so long until the 7 segment display H5000 displays _ 8 After a short pressing of the OPEN S5001 button or the CLOSE...

Страница 4: ...in attachment 11 of the operating instructions Simple settings can also be executed with the three buttons and the 7 segment display of the basic equipment see section 5 WARNING The service staff should test the acceptable energies and forces after the putting into operation of the elevator door on the heaviest door in the complete system elevator and to adjust it to the critical limits in case of...

Страница 5: ...u Therefore set the counterweight last WARNING So that the closing and nudge speed can be limited dependent on the door weight it is imperative that a new teach in drive must be performed after taking over another movement profile start with button S5000 6 Relay contacts option The relay contacts of the optional relay module can be set to relay the following door statuses to the elevator control o...

Страница 6: ...of an adjusted parameter always takes place in the door position CLOSE Menu of the HT18 ESC Jump to RESET SIEMENS AT18 USER TERMINAL LANGUAGE MENU German LANGUAGE MENU English MAIN MENU Total alignment MAIN MENU Quick alignment MAIN MENU Monitor MAIN MENU Service SERVICE MENU FW version SERVICE MENU Fault Status SERVICE MENU Maintenance SERVICE MENU Special MONITOR MENU Door status MONITOR MENU In...

Страница 7: ... Condensed Operating Manual for Door Control Unit AT18 ...

Страница 8: ...0 6 13 Acil durumda akým beslemesi opsiyonel 11 6 14 Aþýrý yük emniyeti 11 7 Mekanik montaj ve ayarlar 12 8 Elektriksel ayarlar ve kullanýma alým 13 9 Röle temaslar Opsiyon 16 10 Hareket eðrisi 18 11 Çalýþma konumu göstergesi 19 12 Hýz sýnýr eðrisi 20 13 Geliþim modülü Opsiyon 21 13 1 Geliþtirme modüllerinin montajý 21 13 2 Acil akým modülü 25 13 2 1 AT18 ile acil durum modülünün baðlantýsý 25 14 ...

Отзывы: