Condensed Operating Manual for Door Control Unit AT8

.  Connect the light barrier to X6 (see illustration  or lid imprint).
 

Insofar as the light barrier input is not used, X6 must be wired to X4 according to the lines on the  

 

connection layout.

3.  Plug in clip plugs X6 and X4.

CAREFUL

The control is operative after the next switch-on. At a presented control signal the door moves into the 

specified direction.

4.  Switch control on (plug in mains current plug, or plug 

X3

).

 

The four LEDs next to the plug-in connector X3 indicate which control signal is active at the 
time. Thereby the LED for the light barrier should glow continuously, if there is no obstacle in the 
movement area of the door.

5.  At a presented control signal 

“CLOSE”

 the door closes with the initial speed in the 

“CLOSE”

 position.

 

At a presented control signal 

“OPEN”

 the door opens with the initial speed in the 

“OPEN”

 position.

16.  If the control has recognized the final door positions 

“OPEN”

 and 

“CLOSE”

, the subsequent opening 

and closing movements are performed in the normal speed.

17.  For special applications the movement values can be specifically adapted to the door. However, for 

that the terminal module (option), the user terminal HT8 (HT5) must be connected to a PC, or 
be connected via a USB adapter (option), on which the operating program AT Frontend has been 
started. The operation is described in attachment  of the operating instructions.

Simple settings can also be executed with the three buttons and the 7-segment display of the basic 
equipment (see section 5). 

WARNING

The service staff should test the acceptable energies and forces after the putting into operation of the 
elevator door on the heaviest door in the complete system (elevator) and to adjust it to the critical 
limits in case of an exceeding of the values. 

5   Electrical configuration with the “MinimalEditor”

The simple adjustability of the profile and of the closing forces is indicated as minimal editor via the 

three internal buttons with the aid of the 7-segment display. For this purpose no terminal module, 
user terminal or AT Frontend PC is necessary. The closing force is set in the form of a counterweight, 

whereby simplified 1kg to 10N is calculated. This value must be deducted from the maximum value 

50N. 

Configuration:

.   Start of the minimal editor: press service button – 

“OPEN”

 and – 

“CLOSE”

 (S500 and S500) 

immediately at the same time as supplying the mains current and keep pushed in.

 

The LED display (H5000) displays an 

“8”

 for approximately 5 seconds.

.   Let go of both buttons after switch-off of the LED display “8”.
3.   After approximately 3s a 

“C”

 (movement profile) and a numerical value is displayed alternatively. 

The displayed numerical value represents the profile number deposited in the AT18.

4.   The desired profile can be selected with the service buttons – 

“OPEN”

 and – 

“CLOSE”

 (S500, or 

S500).

5.   The set value is saved by a long pressing of (>s) of the parameter button (S5000). A dot appears 

Содержание AG AT18

Страница 1: ... Condensed Operating Manual for Door Control Unit AT18 Rev 09 Issue Date 8 2007 www siemens de edm SIDOOR Condensed Operating Manual AT18 ...

Страница 2: ...dge Close Open X7 Motor plug X8 Connection for user terminal and USB adapter AT Frontend PC H5000 7 segment display for door status and error code S5000 Door parameter button S5001 Service button OPEN S5002 Service button CLOSE Relay module Option X11 Relay output CLOSE X12 Relay output Reversed X13 Relay output OPEN X14 Flat cable connection to the control unit Terminal module Option X15 Flat cab...

Страница 3: ...tion 2 Open housing lid 3 Plug in motor plug X7 4 Connect mains current transformer to mains 230 V AC The onsite fuse protection should be a maximum of 10A 5 Press red DOOR PARAM button S5000 and keep pushed in 6 Connect mains current transformer with X3 7 Press red DOOR PARAM button so long until the 7 segment display H5000 displays _ 8 After a short pressing of the OPEN S5001 button or the CLOSE...

Страница 4: ...in attachment 11 of the operating instructions Simple settings can also be executed with the three buttons and the 7 segment display of the basic equipment see section 5 WARNING The service staff should test the acceptable energies and forces after the putting into operation of the elevator door on the heaviest door in the complete system elevator and to adjust it to the critical limits in case of...

Страница 5: ...u Therefore set the counterweight last WARNING So that the closing and nudge speed can be limited dependent on the door weight it is imperative that a new teach in drive must be performed after taking over another movement profile start with button S5000 6 Relay contacts option The relay contacts of the optional relay module can be set to relay the following door statuses to the elevator control o...

Страница 6: ...of an adjusted parameter always takes place in the door position CLOSE Menu of the HT18 ESC Jump to RESET SIEMENS AT18 USER TERMINAL LANGUAGE MENU German LANGUAGE MENU English MAIN MENU Total alignment MAIN MENU Quick alignment MAIN MENU Monitor MAIN MENU Service SERVICE MENU FW version SERVICE MENU Fault Status SERVICE MENU Maintenance SERVICE MENU Special MONITOR MENU Door status MONITOR MENU In...

Страница 7: ... Condensed Operating Manual for Door Control Unit AT18 ...

Страница 8: ...0 6 13 Acil durumda akým beslemesi opsiyonel 11 6 14 Aþýrý yük emniyeti 11 7 Mekanik montaj ve ayarlar 12 8 Elektriksel ayarlar ve kullanýma alým 13 9 Röle temaslar Opsiyon 16 10 Hareket eðrisi 18 11 Çalýþma konumu göstergesi 19 12 Hýz sýnýr eðrisi 20 13 Geliþim modülü Opsiyon 21 13 1 Geliþtirme modüllerinin montajý 21 13 2 Acil akým modülü 25 13 2 1 AT18 ile acil durum modülünün baðlantýsý 25 14 ...

Отзывы: