1.2 Safety 

Notes 

 
These operating instructions contain notes that are to be complied with 
for your personal safety as well as to avoid property damages. These 
notes are marked by a triangular warning symbol and the different 
degrees of danger are categorized as follows:  
 

 

Danger 

Disregard of the corresponding precautionary 
measures will cause death, severe bodiliy injury or 
considerable property damage.  

 
 

 

Warning 

Disregard of the corresponding precautionary 
measures may cause death, severe bodiliy injury 
or considerable property damage.  
 
 

 

Attention 

Disregard of the corresponding precautionary 
measures may lead to slight bodiliy injury or minor 
property damage  
 
 

 

Note 

Shall draw your attention to special information on 
the product, product handling or the corresponding 
section of the documentation. 

 
 

 Qualified 

personnel

 

Commissioning and operation of the equipment is 
to be performed by qualified personnel only. In the 
context of safety notes in this manual, the term 
qualified personnel refers to persons authorized to 
perform commissioning, grounding and labelling of 
devices, systems and electrical circuits. 
 

 

19.10.2006 

Mini-Starcoupler 

Page 5 of 28

 

Содержание 7XV5450-0 A00 Series

Страница 1: ...Mini Starcoupler 7XV5450 0xA00 Operating Instructions Oct 2006 ...

Страница 2: ...ssion 13 3 5 Interference immunity 14 3 6 Climatic Stress tests 15 3 7 Mechanical Stress Tests 16 3 8 Dimension Drawings 17 3 9 Ordering Data 17 4 DESCRIPTION OF THE FUNCTIONAL UNIT 18 4 1 Terminal Assignment 18 4 2 Screw type terminals X2 X7 19 4 3 RS232 Connector X1 19 4 4 FO Connections 20 4 5 Switch positions 20 Assignment Switch 1 21 5 INSTALLATION AND COMMISSIONING 22 5 1 Reference to Instal...

Страница 3: ...y instructions and warnings given in this document in a general manner This manual is an integral part of the scope of delivery However it cannot take into account every detail on all types of the described product and also every possible case regarding installation operation or maintenance If further information is desired or in case special problems should arise which are not treated adequately ...

Страница 4: ...uct itself is personnel involved in planning and configuration activities and familiar with the safety concepts used in automation engineering operating personnel trained for working with automation systems and familiar with the content of this manual as far as it deals with operational aspects commissioning and service personnel having adequate training and qualification to repair this type of au...

Страница 5: ...se death severe bodiliy injury or considerable property damage Attention Disregard of the corresponding precautionary measures may lead to slight bodiliy injury or minor property damage Note Shall draw your attention to special information on the product product handling or the corresponding section of the documentation Qualified personnel Commissioning and operation of the equipment is to be perf...

Страница 6: ...ipment or compounds recommended or accepted by Siemens Faultless and safe operation of the product require proper transport storage mounting and installation as well as careful operation and maintenance 1 4 Explanation of the symbols at the device Danger Warning of a danger Please read the documentation To be operated only by qualified personnel Double insulation Page 6 of 28 Mini Starcoupler 19 1...

Страница 7: ...be included in the next edition You are invited to send us your suggestions for improvement 1 6 Copyright Copyright Siemens AG 2000 All rights reserved Transmission or reproduction of this document as well as the use and forwarding of its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant or registrat...

Страница 8: ... PC via the mini star coupler s receiving and transmitting interface It is thus possible to optically connect up to four terminal units to a central unit Cascading of the mini star coupler is possible All optical inputs and outputs full duplex have ST BOFC connectors and can be set individually to Light ON or Light OFF in idle state Data transmission is transparent i e protocol independent The wav...

Страница 9: ...2 4 Data Transfer Operation of the mini star coupler is transparent and full duplex Data received from the master unit are forwarded by the receiver of channel 1 to all outputs channels 2 3 4 and 5 Data from one of the outputs channel 2 3 4 and 5 are sent to the transmitter of channel 1 The logic of the optical interfaces is positive Light OFF in idle state incoming light signals are treated as ac...

Страница 10: ...RxD GND 7XV5100 4 Notebook PC 9 pol female Starcoupler 9 pol male for Starcoupler 7 8 5 legth 3m 2 6 FO Connections The receiving optical connectors are marked with Rx the transmitting connections with Tx ATTENTION Please tight the mechanical screw connections of the FO cables with FSMA plug carefully and only by hand do not use tools The ST plugs are to be shifted with the lateral nose into the g...

Страница 11: ...C voltage AC voltage 24 V 250 V DC 20 24 V 230 V AC 20 45 65 Hz 1 25 A slow blow not exchangeable III With UH UHN typical value 3 W 2 5 W 3 5 VA Alarm relay 1 Relay Connector Test voltage Switching voltage nominal value Switching capability Switching current Fault indicator MSR Relay 1 NC open contact potential free 2 pol Phönix terminal 3 7 kVeff 250 V DC 20 W VA 1 A permanent LED green 5 V o k R...

Страница 12: ... on Input channel 1 820 nm 19dBm with 50 125µm multimode fibre 15dBm with 62 5 125µm multimode fibre 6 2dBm with 200µm HCS fibre 30dBm 10dB 3 dB system budget safety margin 3 0 km with 62 5 125µm multimode fibre 1 5 km in combination with SIPROTEC systems with 62 5 125µm multimode fibre 3 5 m with 980 1000 plastic fibre 9600 115200 Baud 3 2 Safety Tests Safety tests according DIN EN 61010 Part1 Ov...

Страница 13: ... with bypass capacitors 3 7 kV AC 50Hz 1s without bypass capacitors 5 kV peak 1 2 50 µs 0 5 J 3 pos and 3 neg surges in intervals of 5 s all circuits class III not on open contacts 3 4 Interference Emission Interference Emission Standard EN 50081 1 Conducted interference only power supply voltage IEC CISPR 22 EN55022 VDE 0878 Teil 22 Radio interference field strength IEC CISPR 22 EN55022 VDE 0878 ...

Страница 14: ...ion with HF field pulse modulated IEC 61000 4 3 ENV 50140 ENV50204 class III Fast transient disturbance burst IEC 61000 4 4 class IV IEC 60255 22 4 class IV EN 61000 4 4 class IV 1 MHz 400 surges per s dur 2 s 2 5 kV longit voltage 1 0 kV transverse voltage 4 kV contact discharge 8 kV air discharge both polarities 150 pF Ri 330 Ohm 10 V m 27 MHz to 500 MHz 10 V m 80 MHz to 1000 MHz 80 AM 1kHz 10 V...

Страница 15: ...150 kHz to 80 MHz 80 AM 1 kHz 30 A m permanent 300 A m during 3 s 50 Hz 3 6 Climatic Stress tests Ambient Temperatures Recommended operating temperature Limiting temporary transient operating Limiting temperatutre during storage packing from the factory Limiting temperature during transport packing from factory Permissible humidity 5 C to 55 C 23 F to 131 F 20 C to 70 C 4 F to 158 F 25 C to 55 C 1...

Страница 16: ...ration Frequency sweep rate 10 oktave min 20 cycles in 3 orthogonal axes semi sinusoidal Acceleration 5 g duration 11 ms 3 shocks in each direction of 3 orthogonal axes sinusoidal 1 Hz to 8 Hz 3 5mm amplitude horizontal axis 1 Hz to 8 Hz 1 5mm amplitude vertical axis 8 Hz to 35 Hz 1g acceleration horizontal axis 8 Hz to 35 Hz 0 5g acceleration vertical axis Frequency sweep rate 1 octave min 1 cycl...

Страница 17: ...UN SLAVE MASTER T3 R3 T2 R2 T1 R1 UH UH L1 L 1 2 M1 X2 X7 105 90 90 90 75 Fig 1 Dimension Drawings 3 9 Ordering Data Name Order No Mini Starcoupler 7 X V 5 4 5 0 0 A 0 0 with 1 FO Interface input and 4 FO Interface output and 1 RS232 Interface Optical In Output BFOC ST connector B 19 10 2006 Mini Starcoupler Page 17 of 28 ...

Страница 18: ...minals or to the 9 pin SubD socket The fiber optic channel are connected by BOFC ST terminals The unit is free of silicone and halogen as well as flame retardant 4 1 Terminal Assignment N L T4 R4 T5 R5 Mini Starcoupler 7XV5450 0AA00 SERIES A4 K7 655430 C E 5 5 24 250V DC 60 230V AC RUN SLAVE MASTER T3 R3 T2 R2 T1 R1 UH UH L1 L 1 2 M1 X2 X7 Input X1 Tx FO transmitter Rx FO receiver X2 Power supply ...

Страница 19: ...ted 2 Send data RxD 3 Receive data TxD 4 not connected 5 Signal ground GND 6 not connected 7 Activation of the RS232 interface 8 Signal ground GND 9 not connected Tab 2 RS232 Connector Sub D 9 pol female X1 For activation of the RS232 interface pins 7 and 8 must be jumpered and switch S1 S2 must be closed Note If the cascade connection is wired in star topology and S1 switch 1 is ON ring cascade c...

Страница 20: ...pre settings i e All FO transmitters receivers set to light off in idle state Cascading for star configuration RS232 interface disabled X1 X2 X7 OFF S1 ON 1 2 3 4 5 6 7 8 Down view Fig 3 Switch positions S1 Note If the switch S1 1 is set to ring configuration the signals are generally mirrored to the Master echo This also applies to the star configuration With various devices or pc applications th...

Страница 21: ...state Channel 4 Light OFF in idle state Channel 4 5 open off closed on Light ON in idle state Channel 5 Light OFF in idle state Channel 5 6 open off closed on Light ON in idle state Channel 1 Light OFF in idle state Channel1 7 open off closed on Light ON in idle state Channel 2 Light OFF in idle state Channel 2 8 open off closed on Light ON in idle state Channel 3 Light OFF in idle state Channel 3...

Страница 22: ...itted only for operation within enclosed housings or cabinets and places of installation are to be accessible only for qualified personnel The device is clipped on a 35 mm top hat rail according to EN50022 The installation location should be free of vibrations The admissible temperature operation or functional temperature is to be observed see technical data Disregard of the temperature range requ...

Страница 23: ...tacts are screwed on terminal X7 at he bottom side of the device The assignment of the terminals is printed at the front side or can be read in this manual Connection to screw terminals Terminal cross section max 2 5 mm2 Stripping length 3 bis 5 mm Cable cross section 0 14 bis 1 5 mm2 Single core cable or litz wire 5 2 3 Fibre Optic FO connections Rx Tx Only optical fibres prepared according the r...

Страница 24: ...void any dust at the FO connections Connect to RS232 terminals and screw them for permanent use Connect the alarm relay terminals X7 Connect auxiliary power to the terminals X2 DC L AC L1 and DC L AC N The device is ready for use after switching on the auxiliary power The green LED RUN lights up 5 4 Maintenance The signal converter requires no maintanance For cleaning please use a dry and free of ...

Страница 25: ...Anr Erde Automat RUN ERROR SIEMENS RUN ERROR Anr L1 Anr L2 FO RS485 Converter 7XV5650 DIGSI Modem 7XV5101 Substation modem 7XV58xx Modem Office modem 7XV58xx Private or public network V3 V3 V4 V4 FO cable 6XV81xx RS485 Bus cable 7XV5103 DIGSI cable 7XV5100 4 Converter 7XV5101 0B Office PC SIPROTEC SIEMENS L1 402 1A Max450 1A L2 402 1A Max450 1A L3 402 1A Max450 1A E 00 0A Anr L1 Anr L2 Anr L3 Anr ...

Страница 26: ...Max450 1A L3 402 1A Max450 1A E 00 0A Anr L1 Anr L2 Anr L3 Anr Erde Automat RUN ERROR SIEMENS RUN ERROR Anr L1 Anr L2 FO RS485 Converter 7XV5650 DIGSI Modem 7XV5101 Substation modem 7XV58xx Modem Office modem 7XV58xx Private or public network V3 V3 V4 V4 FO cable 6XV81xx RS485 Bus cable 7XV5103 DIGSI cable 7XV5100 4 Converter 7XV5101 0B Office PC SIPROTEC SIEMENS L1 402 1A Max450 1A L2 402 1A Max4...

Страница 27: ...s zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Span nungsgrenzen geändert durch 93 68 EWG Council Directive on the approximation of the laws of the Member States related to electrical equipment designed for use within certain voltage limits amended by 93 68 EEC Die Konformität mit den Richtlinien wird nachgewie...

Страница 28: ...bution Power Automation Depart PTD PA 13 Postfach 4806 D 90026 Nürnberg Telefax 49 911 433 8301 Further informations regarding our products in the INTERNET under http www SIPROTEC com or please visit our Download Area which is part of our WEB site where also the latest version of this manual is available as a PDF file Printed in Germany ...

Отзывы: