2.5
Connection to a PC with Serial Interface
For central remote, the serial interface of the star coupler can be
connected to a PC by means of a serial cable. Pins 7 and 8 of this cable
must be jumpered. (Note that this deactivates FO Input channel 1).
The serial interface distributes data to the four FO channels and receives
data from these channels.
Assignment 7XV5100-4
2
3
4
6
7*
8*
5
3
2
TxD
RxD
GND
7XV5100-4
Notebook / PC
9-pol. female
Starcoupler
9-pol. male
* for Starcoupler
7
8
5
legth 3m
2.6 FO-Connections
The receiving optical connectors are marked with Rx, the transmitting
connections with Tx.
ATTENTION! Please tight the mechanical screw connections of the FO -
cables with FSMA plug carefully and only by hand (do not use tools).
The ST plugs are to be shifted with the lateral nose into the groove of the
device connection and locked afterwards. During the installation of the
FO - cables the bending radius specified for the cable is to be kept.
Page 10 of 28
Mini-Starcoupler