FNo.Abbreviation Meaning
OpFtEIOT
¨©©©©ª©©©©©©©©©©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©ª©©©
4556Ext 2 Gen.FltExternal trip 2: General fault det.
CG O
4557Ext 2 Gen.TrpExternal trip 2: General trip
C OT
4563>Ext 3 block >Block external trip 3
IO
4566>Ext trip 3 >Trigger external trip 3
CG IO
4571Ext 3 off
External trip 3 is switched off
CG O
4572Ext 3 blockedExternal trip 3 is blocked
CG O
4573Ext 3 active External trip 3 is active
CG O
4576Ext 3 Gen.FltExternal trip 3: General fault det.
CG O
4577Ext 3 Gen.TrpExternal trip 3: General trip
C OT
4583>Ext 4 block >Block external trip 4
IO
4586>Ext trip 4 >Trigger external trip 4
CG IO
4591Ext 4 off
External trip 4 is switched off
CG O
4592Ext 4 blockedExternal trip 4 is blocked
CG O
4593Ext 4 active External trip 4 is active
CG O
4596Ext 4 Gen.FltExternal trip 4: General fault det.
CG O
4597Ext 4 Gen.TrpExternal trip 4: General trip
C OT
5002Operat. Cond.Suitable measured quantities present
CG O
5004>Phase rotat.>Phase rotation counter-clockwise
CG IO
5005Clockwise
Phase rotation is clockwise
C O
5006Counter-clockPhase rotation is counter-clockwise
C O
5173>U0> block
>Block stator earth fault protection
IO
5181U0> off
Stator earth fault prot. is switch off CG O
5182U0> blocked Stator earth fault protection is block.CG O
5183U0> active
Stator earth fault protection is activeCG O
5186U0> Fault
Stator earth fault: Fault detection U0 CG O
5187U0> Trip
Stator earth fault: Trip U0 stage
C OT
5203>Frq. block >Block frequency protection
IO
5206>f1 block
>Block frequency prot. f1 stage
CG IO
5207>f2 block
>Block frequency prot. f2 stage
CG IO
5208>f3 block
>Block frequency prot. f3 stage
CG IO
5209>f4 block
>Block frequency prot. f4 stage
CG IO
5211FRQ off
Frequency protection is switched off
CG O
5212FRQ blocked Frequency protection is blocked
CG O
5213FRQ active
Frequency protection is active
CG O
5214FRQ U< block Frequency protection blocked by U<
CG O
5216f1> Fault
Frequency protection: Fault stage f1> CG O
5217f1< Fault
Frequency protection: Fault stage f1< CG O
5218f2> Fault
Frequency protection: Fault stage f2> CG O
5219f2< Fault
Frequency protection: Fault stage f2< CG O
5220f3> Fault
Frequency protection: Fault stage f3> CG O
5221f3< Fault
Frequency protection: Fault stage f3< CG O
5222f4> Fault
Frequency protection: Fault stage f4> CG O
5223f4< Fault
Frequency protection: Fault stage f4< CG O
5224f1> Trip
Frequency protection: Trip stage f1>
C OT
5225f1< Trip
Frequency protection: Trip stage f1<
C OT
5226f2> Trip
Frequency protection: Trip stage f2>
C OT
5227f2< Trip
Frequency protection: Trip stage f2<
C OT
5228f3> Trip
Frequency protection: Trip stage f3>
C OT
5229f3< Trip
Frequency protection: Trip stage f3<
C OT
5230f4> Trip
Frequency protection: Trip stage f4>
C OT
5231f4< Trip
Frequency protection: Trip stage f4<
C OT
5353>U/f block
>Block overexcitation protection
IO
5356>RM th.repl. >Reset memory of thermal replica U/f
IO
5361U/f> off
Overexcitation prot. is swiched off
CG O
5362U/f> blocked Overexcitation prot. is blocked
CG O
5363U/f> active Overexcitation prot. is active
CG O
5367U/f> warn
Overexc. prot.: U/f warning stage
CG O
5368U/f> th.warn Overexc. prot.: th. warning stage
CG O