SITRANS P DS III (7MF4.33.. 7MF4.34.. 7MF4.35..)
12
A5E03434626-03, 06/2013
Note
Loss of degree of protection
Damage to device if the enclosure is open or not properly closed. The degree of protection specified on the nameplate or in
"Technical data" (Page 35) is no longer guaranteed.
●
Make sure that the device is securely closed.
See also
Connecting the device (Page 21)
3.2
Disassembly
WARNING
Incorrect disassembly
The following dangers may result through incorrect disassembly:
- Injury through electric shock
- Danger through emerging media when connected to the process
- Danger of explosion in hazardous area
In order to disassemble correctly, observe the following:
●
Before starting work, make sure that you have switched off all physical variables such as pressure, temperature,
electricity etc. or that they have a harmless value.
●
If the device contains dangerous media, it must be emptied prior to disassembly. Make sure that no environmentally
hazardous media are released.
●
Secure the remaining connections so that no damage can result if the process is started unintentionally.
3.3
Installation (except level)
3.3.1
Instructions for installation (except level)
Conditions
Note
Compare the desired operating data with the data on the nameplate.
Please also refer to the information on the remote seal if this is fitted.
Note
Protect the transmitter against:
●
Direct heat radiation
●
Rapid temperature fluctuations
●
Heavy contamination
●
Mechanical damage
●
Direct sunlight
The installation location is to be as follows:
●
Easily accessible
●
As close as possible to the measuring point
●
Vibration-free
●
Within the permitted ambient temperature values
Installation configuration
The transmitter may in principle be configured above or below the pressure tapping point. The recommended configuration
depends on the aggregate state of the medium.