Diagnostics and maintenance
5.4 Device replacement in the event of a fault
SIMATIC CC7
Operating Instructions, 10/2019, C79000-G8976-C503-02
123
●
Deleted data
The following data is deleted in the gateway by resetting to factory settings:
–
Addresses of the LAN interfaces configured by the user
They are reset to the factory default address data.
–
All other configuration data of the gateway
–
All process data in the memory of the gateway
–
User names and passwords
–
All imported certificates
–
Diagnostics buffer
The following data is also deleted:
–
All data on an inserted CLP
●
Data not deleted
The following data is not deleted by resetting to factory settings:
–
MAC address of the LAN interfaces
Restart after reset
●
The gateway starts up without configuration data.
●
The DHCP client function is disabled.
The gateway can only be reached over the default address data, refer to the section
Establishing a connection to the WBM (Page 52).
5.4
Device replacement in the event of a fault
Device defective
If a fault develops, please send the device to your SIEMENS service center for repair.
Repairs on-site are not possible.
Replacing the gateway
WARNING
Before replacement
•
Before replacing the gateway, read the safety notices in the section Important notes on
using the device (Page 31).
•
While working on the device make sure that the power supply is turned off.
When replacing the gateway follow the steps described in the section Installation (Page 34).
Содержание 6GK1411-1AC00
Страница 10: ...Table of contents SIMATIC CC7 10 Operating Instructions 10 2019 C79000 G8976 C503 02 ...
Страница 30: ...LEDs Connectors Buttons CLP 2 4 CLP Slot SIMATIC CC7 30 Operating Instructions 10 2019 C79000 G8976 C503 02 ...
Страница 136: ...Dimension drawings SIMATIC CC7 136 Operating Instructions 10 2019 C79000 G8976 C503 02 Figure 8 2 Side view ...
Страница 150: ...Index SIMATIC CC7 150 Operating Instructions 10 2019 C79000 G8976 C503 02 ...