![Siemens 6FC5403-0AA21-0AA1 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/siemens/6fc5403-0aa21-0aa1/6fc5403-0aa21-0aa1_equipment-manual_384538049.webp)
Note
If a connection box is to be operated in "E-stop button evaluated by PROFIsafe" mode, the
connection box cannot be wired according to a hardwired F-system.
Requirement
• The connection box standard or advanced is open.
• Required number of connecting cables
• The wires of the connection cables have been stripped by 8 mm.
• Matching ferrules when using flexible cables
Procedure
1. Connection boxes standard and advanced:
Thread the cables through the corresponding screw glands.
2. When you use flexible cables, place a wire end ferrule on each wire to be connected.
3. Insert the wire ends into the associated spring-loaded terminal as shown in the figures below.
The figure below shows the terminals to be connected to the connection box.
①
Terminal for the emergency stop / stop button
②
Terminal for the enabling button
4. Connect the cables.
5. For connection box standard and connection box advanced:
When all the required work has been completed in the connection box, close it.
Connecting
4.4 SIMATIC connection box
Handheld Terminal HT 10
Equipment Manual, 09/2020, A5E47430965B AA
49
Содержание 6FC5403-0AA21-0AA1
Страница 24: ...Dimension drawings Handheld Terminal HT 10 24 Equipment Manual 09 2020 A5E47430965B AA ...
Страница 76: ...Commissioning 5 5 Troubleshooting Handheld Terminal HT 10 76 Equipment Manual 09 2020 A5E47430965B AA ...
Страница 78: ...Maintenance and Service Handheld Terminal HT 10 78 Equipment Manual 09 2020 A5E47430965B AA ...
Страница 92: ...Spare parts Handheld Terminal HT 10 92 Equipment Manual 09 2020 A5E47430965B AA ...