Connection via the SIMATIC HMI connection box advanced allows quick connection and
disconnection during machine operation without tripping an emergency stop.
NOTICE
Damage through regenerative feedback
Regenerative feedback of voltage to ground by a connected or installed component can
damage the device.
Connected or built-in I/Os, for example a USB drive, are not permitted to supply any voltage to
the device. Regenerative feedback is generally not permitted.
4.2
Pin assignment of the interfaces
I
Signal input
O
Signal output
B
Bi-directional signal
V
Supply voltage
K
Contact
VI
Voltage input
VO
Voltage output
See also
Pin assignment of the interfaces (Page 26)
4.2.1
Power supply
Connector designation: X 51
Connector type:
12-pole connector plug with coding and locking
Pin
Signal name
Signal type
Signal
type
1
nc
2
nc
3
ENABLE 2+
(Enabling button channel 2, digital)
I
4
ENABLE 2-
(Enabling button channel 2, digital)
O
5
ENABLE 1+
Enabling button channel 1, digital
I
6
ENABLE 1-
Enabling button channel 1, digital
O
7
STOP -13
EMERGENCY STOP circuit 2
K
8
STOP -14
EMERGENCY STOP circuit 2
K
Connecting
4.2 Pin assignment of the interfaces
Handheld Terminal HT 10
26
Equipment Manual, 09/2020, A5E47430965B AA
Содержание 6FC5403-0AA21-0AA1
Страница 24: ...Dimension drawings Handheld Terminal HT 10 24 Equipment Manual 09 2020 A5E47430965B AA ...
Страница 76: ...Commissioning 5 5 Troubleshooting Handheld Terminal HT 10 76 Equipment Manual 09 2020 A5E47430965B AA ...
Страница 78: ...Maintenance and Service Handheld Terminal HT 10 78 Equipment Manual 09 2020 A5E47430965B AA ...
Страница 92: ...Spare parts Handheld Terminal HT 10 92 Equipment Manual 09 2020 A5E47430965B AA ...