background image

Markings and symbols 

 

B.4 Certificates, approvals and markings 

 

SIMATIC IOT2050 

64

 

Operating Instructions, 03/2020, A5E39456816-AA 

B.4

 

Certificates, approvals and markings 

The following table shows symbols relating to certificates, approvals and markings which 

may be on the device. You can find more information in the operating instructions for your 

device: 

 

Symbol 

Meaning 

 

Symbol 

Meaning 

 

 

Approved for Australia and New Zea-

land 

 

 

Marking for the Eurasian Customs 

Union 

 

Approved for China 

 

Test mark of Factory Mutual Re-

search 

 

CE markings for European countries 

 

Marking of Federal Communications 

Commission for the USA 

 

EFUP (Environment Friendly Use 

Period) marking for China 

 

Approved for Korea 

 

Test mark of the Underwriters La-

boratories 

 

Disposal information, observe the 

local regulations. 

 

Approval for India 

 

 

 

Содержание 6ES7647-0BA00-0YA2

Страница 1: ...afety instructions 2 Installing and connecting the device 3 Software and commissioning 4 Expand device 5 Maintaining and repairing the device 6 Certificates and approvals 7 Dimension drawings 8 Technical specifications 9 Hardware descriptions 10 Technical support A Markings and symbols B List of abbreviations C ...

Страница 2: ...by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens product...

Страница 3: ...owledge in the field automation control engineering is recommended Scope of validity of this document These operating instructions apply to the IOT2050 devices of the device family SIMATIC IOT2000 6ES7647 0BA00 0YA2 6ES7647 0BA00 1YA2 Scope of this documentation The device documentation comprises Product information for example Important notes on your device Quick Install Guide SIMATIC IOT2050 SIM...

Страница 4: ...hines and networks Such systems machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures e g firewalls and or network segmentation are in place For additional information on industrial security measures that may be implemented please visit https www siemens com industria...

Страница 5: ... mounting types 17 3 2 Mounting the device 18 3 2 1 Mounting instructions 18 3 2 2 Mounting on DIN rails 19 3 2 2 1 Secure the mounting clips 19 3 2 2 2 Mounting on DIN rails 21 3 2 3 Wall mounting 22 3 2 3 1 Vertical wall mounting 22 3 2 3 2 Horizontal wall mounting 23 3 3 Connecting the device 24 3 3 1 Notes on connecting 24 3 3 2 Connecting the function earth 25 3 3 3 Connecting the power suppl...

Страница 6: ...demand of the components 51 9 4 Direct current supply DC 51 10 Hardware descriptions 52 10 1 Motherboard 52 10 2 External Interfaces 54 10 2 1 Power supply 54 10 2 2 USB 54 10 2 3 Ethernet port 54 10 2 4 Serial port 55 10 3 Internal interfaces 56 10 3 1 Arduino shield interfaces 56 10 3 2 UART Debug 58 10 3 3 Mini PCIe interface 59 10 3 4 Micro SD interface 59 10 3 5 DisplayPort 1 1A 60 A Technica...

Страница 7: ...t compact and flexible solution with a focus on the IOT environment and round off the SIMATIC IPC product range in the lower output range Features High degree of ruggedness Compact design External RS232 RS422 RS485 Ethernet DP and USB interfaces Internal interfaces for Arduino Shield and Mini PCIe card Freely programmable interfaces Maintenance free ...

Страница 8: ...he industrial area of application the following SIMATIC IOT devices are available with the following features 6ES7647 0BA00 0YA2 6ES7647 0BA00 1YA2 Processor TI SOC AM6528 GP Dual Core TI SOC AM6548 HS Quad Core with High Security possibility RAM 1 GB RAM DDR4 2 GB RAM DDR4 eMMC No 16 G Battery buffered real time clock No Yes ...

Страница 9: ... following figures show the configuration and interfaces of the SIMATIC IOT2050 Ethernet interfaces 100 1000 Mbps LED display see section Motherboard Page 52 USB Type A RESET button for the CPU DisplayPort 1 1 A Markings for mini PCIe installation accessory COM interface RS232 422 485 Shield cover Power supply connector Top housing USER button programmable ...

Страница 10: ...f the operating instructions You will find additional accessories on the Internet at Industry mall https mall industry siemens com Name Specification Order number DisplayPort line 3 m long 6AV7860 0DH30 0AA0 5 m long 6AV7860 0DH50 0AA0 Arduino Shield SIMATIC IOT2000 Input Output Module 5 x DI 2 x AI 2 x DO 6ES7647 0KA01 0AA2 SIMATIC IOT2000 Input Module Sink Source 10 x DI 6ES7647 0KA02 0AA2 ...

Страница 11: ...hine or plant The installation of expansions can damage the device machine or plant Device and system expansions might violate safety rules and regulations regarding radio interference suppression If you install or exchange system expansions and damage your device the warranty becomes void Note the following for system expansions Only install system expansion devices designed for this device Conta...

Страница 12: ...ll technical specifications and approvals of the device only apply if you use expansion components that have a valid CE approval CE mark The installation conditions for expansion components in the associated documentation must be observed UL approval of the device only applies when the UL approved components are used according to their Conditions of Acceptability We are not liable for functional l...

Страница 13: ...cell body do not recharge do not open do not short circuit do not reverse polarity do not heat above 100 C and protect from direct sunlight moisture and condensation Strong high frequency radiation NOTICE Observe immunity to RF radiation The device has an increased immunity to RF radiation according to the specifications on electromagnetic compatibility in the technical specifications Radiation ex...

Страница 14: ...orrect functioning of the plant to avoid functional restrictions Note Use in an industrial environment without additional protective measures This device is designed for use in a normal industrial environment according to IEC 60721 3 3 Security notification Follows the security rules for networks Install hardware firewall before connecting to internet Install software firewall on the device and op...

Страница 15: ...ng in case you have to transport the unit again Note Damage to the device during transport and storage If a device is transported or stored without packaging shocks vibrations pressure and moisture may impact the unprotected unit A damaged packaging indicates that ambient conditions have already had a massive impact on the device The device might be damaged Do not dispose of the original packaging...

Страница 16: ... off the device for immediate repair NOTICE Damage from condensation If the device is subjected to low temperatures or extreme fluctuations in temperature during transportation for example in cold weather moisture could build up on or inside the device condensation Moisture causes a short circuit in electrical circuits and damages the device In order to prevent damage to the device proceed as foll...

Страница 17: ... illustration shows an example Example rating plate Enter the identification data in the table below Order number 6ES Serial number S VP Production version FS All existing Ethernet ad dresses MAC 3 1 3 Permitted mounting positions and mounting types The device can be mounted horizontally or vertically on a DIN rail or to a wall Vertical mounting position preferred Horizontal mounting position Cons...

Страница 18: ...operation only For installation in a cabinet observe the SIMATIC setup guidelines http support automation siemens com WW view de 1064706 as well as the relevant DIN VDE requirements or the applicable country specific regulations When the device is used in the area of Industrial Control Equipment in accordance with UL61010 2 201 note that the device is classified as Open equipment Install all the e...

Страница 19: ...rs and screws other than those specified below for wall mounting safe mounting is not guaranteed The device can fall and may be damaged Only use the anchors and screws specified in the following table Material Bore diameter Fixing element Concrete Select according to the speci fication of the mounting ele ments used Anchor 6 mm 40 mm long Screw 4 mm 40 mm long Plasterboard at least 13 mm thick Tog...

Страница 20: ...ay the rail clamp on the rear of the device 2 Fasten the rail clamp with the supplied screws Secure the mounting clips for horizontal mounting 1 Lay the rail clamp on the rear of the device 2 Fasten the rail clamp with the two supplied screws 3 Lay the brackets on the rear of the device Align the bracket edge with the device edge 4 Fasten the brackets with the supplied screws ...

Страница 21: ...tandard profile rail at the position shown and push the device down 2 Swing the rail clamp of the device from below through the standard profile rail 3 Push the device in the direction of the standard profile rail You will hear the device click into place Vertical Horizontal Removing 1 Push down the device until it is released by the rail clamp 2 Swing the device out of the standard profile rail 3...

Страница 22: ...ble for horizontal or vertical wall mounting Note The device must be installed on the plate of an enclosure Requirement Two mounting brackets Two screws T8 screwdriver Procedure for mounting 1 Lay the mounting brackets on the rear of the device 2 Fasten the brackets with supplied screws 3 Mark the bore holes drill the required holes in the wall and fasten the device to the wall using two screws ...

Страница 23: ...ing The device is suitable for horizontal or vertical wall mounting Requirement Two mounting brackets Two screws T8 screwdriver Procedure for mounting 1 Lay the mounting brackets on the rear of the device 2 Fasten the brackets with supplied screws 3 Mark the bore holes drill the required holes in the wall and fasten the device to the wall using two screws ...

Страница 24: ...pply lines that are connected to the device with terminals e g 24 VDC power supply cables to the 24 VDC power supply connectors Utiliser des câbles en cuivre sur les connexions à bornes Utilisez des câbles en cuivre Cu pour tous les câbles d alimentation qui sont raccordés à l appareil par des bornes par exemple les câbles d alimentation 24 V CC sur le connecteur d alimentation 24 V CC NOTICE Faul...

Страница 25: ...rite magnet 3 3 2 Connecting the function earth A connected function earth discharges electrical charges from the metal enclosure The function earth also improves the discharge of interference generated by external power cables signal cables or cables for I O modules to ground The connection for the function earth is labeled with the following symbol WARNING Electric shock and risk of fire High vo...

Страница 26: ...ed Connect the function earth to the protective conductor con nection of the cabinet or the plant in which the device is in stalled 3 3 3 Connecting the power supply Note The device should only be connected to a 12 to 24 V DC power supply which meets the requirements of safe extra low voltage SELV according to IEC EN DIN EN UL 61010 1 Note The power supply must be adapted to the input data of the ...

Страница 27: ...rminal A two core cable meet the following requirements a copper Cu cable with cross section of 0 75 mm2 to 2 5 mm2 rated temperature 70 C A slotted screwdriver with a 3 mm blade Procedure 1 Switch off the power supply 2 Connect the lines to the connecting terminal with a torque of 0 56 Nm 5lb in 3 Connect the connecting terminal to the connection for the power supply ...

Страница 28: ...n Always wear protective gloves before touching the device La surface de l appareil peut atteindre une température supérieure à 70 Vous risquez de vous brûler au contact de l appareil si vous ne portez pas de gants de protection Évitez le contact direct avec l appareil pendant son fonctionnement Portez toujours des gants de protection avant de toucher l appareil SIMATIC IOT2000 Forum To use the SI...

Страница 29: ...ard If you are using the Micro SD card Nano SIM card in a device installed in a system you must observe the safety regulations for work on electrical systems Carefully insert the Micro SD card Nano SIM card into the card holder without applying excess force 1 Open the card cover on the bottom 2 Push the Micro SD card Nano SIM card correctly into the supporting frame The contacts of the Micro SD ca...

Страница 30: ...ontrol and display elements The device loses its approval certificates if you drill or mill openings in the cover in order to make the operator control or display elements of the Arduino shield accessible or visible from outside In this case the customer is responsible for the re approval of the device Note Power consumption If the power consumption of the Arduino shield is too high the device wil...

Страница 31: ...oard Ensure that the contact pins of the Arduino shield fit perfectly on the contact strips of the motherboard and that the components of the Arduino shield do not touch the components of the motherboard Note Customize the shield cover according to the Arduino shield Note Only use fixing elements made from plastic You can use the four boreholes in the motherboard to additionally fasten the Arduino...

Страница 32: ...of the Mini PCIe card is specified accordingly CAUTION Risk of burns due to hot components The motherboard and internal components can get hot during operation Motherboard and internal components will only cool down slowly after the device has been switched off To avoid getting burned wait a while after switching off the power supply Be very careful when opening the enclosure and removing the moth...

Страница 33: ...iate place on the top housing of the enclosure 3 Remove the top housing of the enclosure 4 Drill two holes with a corresponding diameter at the marking shown for mini PCIe installation accessory 5 Insert the Mini PCIe card in the Mini PCIe interface on the motherboard as illustrated 6 Fix the mini PCIe card with two M2 screws 7 Connect the cables of mini PCIe installation accessory to the Mini PCI...

Страница 34: ... 1 Align the bottom of the top housing to the heatsink edge Make sure the marked hooks hooked the heatsink Carefully insert the COM interface into the top housing 2 Insert the two plastic clips of top housing into the clip holes on heatsink 3 Press the top housing to fix the clips Then install power plug and screws for COM interface ...

Страница 35: ...2 Install the half szie Mini PCle cards directly The following example describes the installation of a half size Mini PCIe card including mounting of the antenna jacks If you install a different Mini PCIe card the work steps 5 and 6 are not required Follow steps 1 to 4 as described in Installing Mini PCIe card Page 32 to open the top housing with shield cover Then the following steps 1 Remove one ...

Страница 36: ...TIC IOT2050 36 Operating Instructions 03 2020 A5E39456816 AA 5 Connect the cables of mini PCIe installation accessory to the Mini PCIe card 6 Get the cable of mini PCIe installation accessory out of the housing Then install the top housing Page 32 ...

Страница 37: ...ore you open the device Only install system expansion devices designed for this device If you install other expansion devices you may damage the device or violate the safety requirements and regulations on RF suppression Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed If you install or exchange system expansions ...

Страница 38: ...ing the backup battery For 6ES7647 0BA00 1YA2 only This chapter applies to the device 6ES7647 0BA00 1YA2 which has a back up battery Prior to replacement WARNING Risk of explosion and release of harmful substances Improper handling of lithium batteries can result in an explosion of the batteries Explosion of the batteries and the released pollutants can cause severe physical injury Worn batteries ...

Страница 39: ...are liable to prosecution if you do not properly dispose of batteries and rechargeable batteries Please observe the following when disposing of batteries and rechargeable batteries Dispose of used batteries and rechargeable batteries separately as hazardous waste in accordance with local regulations You can return used batteries and rechargeable batteries to public collection points and wherever b...

Страница 40: ...3 2020 A5E39456816 AA Procedure Remove the power plug and marked screws Loosen the top housing Care fully press with the blade of a flat blade screwdriver in the marked recesses and carefully pull on the appropriate place on the top housing of the en closure Remove the top housing of the enclosure Remove the marked screws on the motherboard ...

Страница 41: ...e display port socket Plug in the battery cable on the motherboard Then install the motherboard again and install the top housing Page 32 6 4 Recycling and disposal Due to the low levels of pollutants in the devices described in these operating instructions they can be recycled Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of you...

Страница 42: ... sections EU Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address AUTOHOTSPOT ISO 9001 certificate The Siemens quality management system for all production processes development production and sales meets the requirements of GB T 19001 2008 ISO 9001 2015 ISO 14001 2015 Cor 1 2009 and BS OHSAS 18001 2007 Certificate registration no...

Страница 43: ...s Modifications Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Conditions of Operations This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference th...

Страница 44: ...Scope of application Requirements for Interference emission Immunity to interference Industrial area EN 61000 6 4 2007 A1 2011 EN 61000 6 2 2005 7 1 2 ESD guideline What does ESD mean An electronic module is equipped with highly integrated components Due to their design electronic components are highly sensitive to overvoltage and thus to the discharge of static electricity Such electronic compone...

Страница 45: ...period of operation The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system Avoid touching components directly Make sure that persons the workstation and the packaging are properly grounded Charge Every person without a conductive connection to the electrical potential of his her surroundings can be electrostatically charged The mater...

Страница 46: ...install or remove modules which are sensitive to ESD Pay attention to good grounding When handling electrostatical sensitive devices make sure that persons the workstation and devices tools and packaging used are properly grounded This way you avoid static discharge Avoid direct contact As a general rule do not touch electrostatic sensitive devices except in the case of unavoidable maintenance wor...

Страница 47: ...SIMATIC IOT2050 Operating Instructions 03 2020 A5E39456816 AA 47 Dimension drawings 8 The following figures show the dimension drawings of the type IOT2050 All dimensions in mm ...

Страница 48: ... supply which meets the requirements of safe extra low voltage SELV according to IEC EN DIN EN UL 61010 1 2 In the event of low supply voltage the buffer time is reduced Electromagnetic compatibility Immunity with regard to conducted interference on the supply lines 2 kV according to IEC 61000 4 4 burst 1 kV according to IEC 61000 4 5 asymmetrical surge Noise immunity on signal lines 1 kV accordin...

Страница 49: ...aces All devices of the type SIMATIC IOT2050 USB Type A X60 2 x USB 2 0 host high current max 2 5 W 500 mA Display port X70 Display port interface LAN interface P1 X1 LAN P2 RJ45 1 1 GB LAN port COM X30 RS232 2 max 115 Kbps D sub connector 9 pin RS422 2 3 max 115 Kbps D sub connector 9 pin RS485 2 3 max 115 Kbps D sub connector 9 pin 1 For unique labeling the LAN interfaces are numbered on the enc...

Страница 50: ...ty tested in accordance with IEC 60068 2 78 IEC 60068 2 30 Operation 5 to 85 at 30 C no condensation Storage transport 5 to 95 at 25 55 C no condensation Atmospheric pressure Altitude Operation 1080 to 795 hPa corresponds to an elevation of 1000 m to 2000 m Storage transport 1080 to 660 hPa corresponds to an elevation of 1000 to 3500 m Also note the following section Power consumption of the compo...

Страница 51: ...ard 1 5 A 1 0 3 A 2 USB 2 0 high current 500 mA 1 May amount to maximum 3 0 A for up to 100 ms at start stop torque of device 2 May amount to maximum 1 2 A for up to 100 ms at start stop torque of device Note Device can overheat The power supply cannot make unlimited power available The auxiliary components consume energy and produce heat The device may overheat The device and the auxiliary compon...

Страница 52: ...SIMATIC IOT2050 52 Operating Instructions 03 2020 A5E39456816 AA Hardware descriptions 10 10 1 Motherboard The following figures show the motherboard of the SIMATIC IOT2050 Pin 1 ...

Страница 53: ... Arduino 8 pin 2x X10 Arduino 10 pin X12 Arduino 6 pin X15 ICSP Part of Arduino Interface X17 DediProg Con X80 Power supply X83 Jumper 3 pin SMD Jumper defines IO voltage for Arduino shield Jumper on pins 1 2 5 V Jumper on pins 2 3 3 3 V X1500 Jumper 3 pin SMD Jumper defines Flash write protection enable or disable Jumper on pins 1 2 write protection ena ble Jumper on pins 2 3 write protection dis...

Страница 54: ...es 10 2 1 Power supply Plug connector 2 pin Name of interface on the device X80 Pin Assignment 1 GND M 2 12 to 24 V DC L 10 2 2 USB USB socket type A Name of interface on the device USB1 X60 USB2 Pin Assignment 1 5 VDC out max 500 mA 2 USB DN 3 USB DP 4 GND 10 2 3 Ethernet port RJ45 socket Name of interface on the device P1 X1 LAN P2 ...

Страница 55: ...nput output 7 BI_DD Bidirectional data D input output 8 BI_DD Bidirectional data D input output LED Short description Meaning 1 LED 1 Connection status Off No data transmission Green flashing Data transmission 2 LED 2 Speed Off Yellow 100 Mbps GREEN 1000 Mbps 10 2 4 Serial port D sub socket 9 pin with screw lock Name of interface on the device X30 COM RS 232 RS 422 RS 485 Assignment RS 232 Pin Sho...

Страница 56: ...4 RX Receive data I for full duplex mode 5 M Signal ground 6 nc 7 nc 8 nc 9 nc Assignment RS 485 Pin Short description Meaning 1 Data Transmit receive data I O for half duplex mode 2 Data Transmit receive data I O for half duplex mode 3 nc 4 nc 5 M Signal ground 6 nc 7 nc 8 nc 9 nc 10 3 Internal interfaces 10 3 1 Arduino shield interfaces The tables below show the pin assignment of the interfaces ...

Страница 57: ...OWER SERIAL SPI I2C PWM 1 8 X 2 9 X 3 10 SS 4 11 MOSI 5 12 MISO 6 13 SCK 7 GND 8 9 SDA 10 SCL X11 Pin Operating mode DIGITAL ANALOG POWER SERIAL SPI I2C PWM 1 0 UART_R x 2 1 UART_Tx 3 2 UART_C TS 4 3 UART_R TS 5 4 X 6 5 X 7 6 X 8 7 X X12 Pin Operating mode DIGITAL ANALOG POWER SERIAL SPI I2C PWM 1 14 A0 2 15 A1 3 16 A2 4 17 A3 5 18 A4 SDA 6 19 A5 SCL ...

Страница 58: ... X13 Pin Operating mode DIGITAL ANALOG POWER SERIAL SPI I2C PWM 1 2 IOREF 3 RESET 4 3 3 V 5 5 V 6 GND 7 GND 8 VIN X15 ICSP Pin Operating mode DIGITAL ANALOG POWER SERIAL SPI I2C PWM A1 12 MISO B1 5 V A2 13 SCK B2 11 MOSI A3 RESET B3 GND 10 3 2 UART Debug X14 Pin Assignment 1 GND 2 RTS_N 3 n c 4 RxD 5 TxD 6 CTS_N ...

Страница 59: ... USB_D 35 GND 36 USB_D 33 PETp0 34 GND 31 PETn0 32 SMB_DATA 29 GND 30 SMB_CLK 27 GND 28 1 5V 25 PERp0 26 GND 23 PERn0 24 3 3Vaux 21 GND 22 PERST 19 Reserved UIM_C4 20 W_DISABLE1 17 Reserved UIM_C8 18 GND Nose 15 GND 16 UIM_VPP 13 REFCLK 14 UIM_RESET 11 REFCLK 12 UIM_CLK 9 GND 10 UIM_DATA 7 CLKREQ 8 UIM_PWR 5 COEX2 6 1 5 V 3 COEX1 4 GND 1 WAKE 2 3 3 Vaux 10 3 4 Micro SD interface X50 Pin Abbreviati...

Страница 60: ...2 GND Ground 3 Lane 0_N Lane 0 Input 4 Lane 1_P Lane 1 Input 5 GND Ground 6 Lane 1_N Lane 1 Input 7 Lane 2_P Lane 2 Input 8 GND Ground 9 Lane 2_N Lane 2 Input 10 Lane 3_P Lane 3 Input 11 GND Ground 12 Lane 3_N Lane 3 Input 13 CONFIG1 Connected to ground 14 CONFIG2 Connected to ground 15 AUX CH_P Auxiliary channel Bidirectional 16 GND Ground 17 AUX CH_N Auxiliary channel Bidirectional 18 Hot plug H...

Страница 61: ...our local representative https www automation siemens com aspa_app Training center http sitrain automation siemens com sitrainworld AppLang en Industry Mall https mall industry siemens com When contacting your local representative or Technical Support please have the following information at hand MLFB of the device BIOS version for industrial PC or image version of the device Other installed hardw...

Страница 62: ...ting terminal to the device You turned the switch on before you connect the DC connecting terminal Avoid turning on off the device by plugging unplugging the DC connecting terminal Use a external switch to control the power of the device User button can t work when Arduino shield reset pin is work ing User button and Arduino inter face reset pin can t work at same time Avoid using user button and ...

Страница 63: ...ymbols on your device may vary in some details from the symbols shown in the following tables B 2 Safety Symbol Meaning Symbol Meaning Warning observe the supplied docu mentation Lock is closed Attention radio equipment Lock is open Disconnect the power plug before opening Opening for Kensington lock Attention ESD Electrostatic sensitive device Warning of hot surface B 3 Operator controls Symbol M...

Страница 64: ...rmation in the operating instructions for your device Symbol Meaning Symbol Meaning Approved for Australia and New Zea land Marking for the Eurasian Customs Union Approved for China Test mark of Factory Mutual Re search CE markings for European countries Marking of Federal Communications Commission for the USA EFUP Environment Friendly Use Period marking for China Approved for Korea Test mark of t...

Страница 65: ...uctor terminal PS 2 keyboard interface Connection for functional earthing equipotential bonding line Multimedia Card Reader DisplayPort interface Smart Card Reader DVI D interface Line In LAN interface not approved for con necting WAN or telephone Line Out Serial port Microphone input USB port Universal Audio Jack USB 2 0 high speed port Headphone output USB 3 0 super speed port USB 3 1 SuperSpeed...

Страница 66: ... Ready for operation DTR Data Terminal Ready Data terminal is ready ESD Components sensitive to electro static charge EN European standard ESD Electrostatic Sensitive Device Electrostatic discharge Electrostatic Sensitive Devices Electrostatic discharge GND Ground Chassis ground IDE Integrated Device Electronics IEC International Electronical Com mission LAN Local Area Network Computer network tha...

Страница 67: ... RxD Receive Data Data transfer signal SELV Safety Extra Low Voltage Safety extra low voltage UEFI Unified Extensible Firmware In terface UL Underwriters Laboratories Inc US organization for testing and certification ac cording to national or binational standards USB Universal Serial Bus ...

Страница 68: ...kernel Linux is a piece of software started by Linus Torvalds and supported by thousands of programmers worldwide FreeBSD is an operating system including a kernel and other software Distribution framework Exemplary reference distribution Debian of Embedded Linux see Debian Drivers Program parts of the operating system They adapt user program data to the specific formats required by I O devices su...

Страница 69: ...f networks is the mutual use of files printers or other resources Module Modules are plug in units for PLCs programming devices or PCs They are available as local modules expansion modules interfaces or mass storage Mass storage module Motherboard The motherboard is the core of the computer Here data are processed and stored and interfaces and device I Os are controlled and managed Operating syste...

Страница 70: ...e of protection 48 Dimension drawings 47 Directive ESD Directive 44 DisplayPort interface 60 E EAC 43 ESD 44 ESD Directive 44 EU Declaration of Conformity 42 Expansion slot 49 F FCC 43 Features 7 Flash 49 function earth 25 Connecting 25 G General technical specifications 48 I Identification data 17 Installation on a DIN rail 17 Installing Arduino shield 30 Backup battery 39 Mini PCIe card 32 Inter...

Страница 71: ... SIMATIC IOT2050 9 Power supply Connecting 26 DC power supply 51 Processor 49 PROFINET 51 Protection class 48 Protective measure Static electricity 46 R Radiation 13 High frequency radiation 13 RAM 49 Rating plate 17 Repairs 37 S Safety instruction Storage 16 Transportation 16 Static electricity Protective measures 46 Supply voltage 48 W Wall mounting 17 22 23 Warranty 11 Weight 48 ...

Отзывы: