h.  If the old controller has the RTS plug 

between the FLN and point terminations, 
rewire power to the power trunk terminal 
block. If the old controller has the RTS plug 
on the opposite end of the board from the 
power trunk terminal block, plug the power 
trunk terminal block from the old controller 
into the new controller. 

NOTE: 

The RTS cable requires a clamp-on 
ferrite filter (Figure 6). Consider strain 
relief to ensure long-term 
effectiveness due to added weight of 
the filter.  

i.  Connect the room temperature sensor. 

j.  Power up the controller. 

k.  Label and remove the polyethylene tubing 

from the old controller. 

l.  After the new controller is in place, 

reconnect the polyethylene tubing. 

4.  Set the address and application at the new 

controller. 

5. Do 

one

 of the following: 

• 

If you updated the initial values from the old 

controller at the field panel, then when you 
set the address and application for the new 
controller, the field panel will automatically 
send the initial values down to the new 
controller. Once this takes place, 
replacement is complete. 

• 

If you manually recorded the initial values in 

the table, then enter them into the new 
controller. If a field panel is present, then 
update the controller’s initial values. 
Replacement is complete. 

• 

If there was no communication at the old 

controller, or the new controller has a newer 
firmware revision than the old controller, 
then enter the initial values into the new 
controller. At the field panel, add the LCTLR 
point and update the controller’s initial 
values. The replacement is complete.

24 V

-AC

FLN TR

UNK

RX

C H GND

+

-

S

BST

TX

RTS

DO1

DO2

DO3

DO4

DO5

DO6

NO C

NO C

NO C

NO C

NO C

NO C

DO7

NO C

DO8

NO C

DI3

DI2

AI3

1   2   3   4   5   6   7   8   9  10 11 12 13 14 15 16 17 18 19 20

1   2   3   4   5   6   7   8   9  10 11 12 13 14 15 16 17 18 19 20

TEC0323R1

+    -    S

C   H   E

CONTROLLER

AIR VELOCITY

SENSOR PORTS

AIR VELOCITY

SENSOR PORTS

IN HOT DUCT

AIR VELOCITY

SENSOR PORTS

IN COLD DUCT

AUTOZERO

MODULE 1

HI

HI

HI

HI

LO

LO

LO

LO

AUTOZERO

MODULE 2

HI

LO

HI

TO TEC

TO AVS

LO

HI

LO

HI

TO TEC

TO AVS

LO

 

Figure 2.  CE Compliant Dual Duct Controller — Two Air Velocity Sensors with Autozero Modules. 

Содержание 550-506

Страница 1: ...50 ft 15 2 m 588 100C 2 RJ11 room temperature sensor cable 100 ft 30 48 m 550 705 clamp on ferrite filter 10 pack Caution Notation CAUTION Equipment damage or loss of data may occur if the user does not follow procedure as specified Required Tools Electro Static Discharge ESD wrist strap Small flat blade screwdriver Medium flat blade screwdriver Medium duty electric drill 1 4 inch 6 35 mm hex nut ...

Страница 2: ... 6 or No 8 screws 3 Place the ESD wrist strap on your wrist and attach it to a good earth ground 4 Carefully remove the controller assembly from the anti static bag Center it over the mounting rail and snap it securely into place 5 Connect the Floor Level Network FLN See Figure 4 6 Connect the point wiring as shown in Figure 7 NOTE Wiring to DI3 AI3 requires a clamp on ferrite filter Figure 6 Stra...

Страница 3: ...ield panel If the old controller does not communicate with the field panel but communicates with CIS or is stand alone record the initial values in Table 1 If the old controller is not communicating or has a newer firmware revision use the following steps to update the field panel a Obtain a field panel Point Definition Report for the LCTLR point Record the values in Table 1 b View the initial val...

Страница 4: ... the new controller the field panel will automatically send the initial values down to the new controller Once this takes place replacement is complete If you manually recorded the initial values in the table then enter them into the new controller If a field panel is present then update the controller s initial values Replacement is complete If there was no communication at the old controller or ...

Страница 5: ...ARENTHESES 4 1 8 105 10 29 32 277 3 16 5 TEC0319R1 C L 11 9 32 287 1 27 32 47 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 S Figure 3 Mounting Dimensions FLN TRUNK RX TX S BST RTS SHIELD SHIELD TEC0272R2 NOTE DO NOT ground the shield 24 V AC H C GND DO1 DO2 DO3 DO4 DO5 NO C NO C NO C NO C NO C NO 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 1 COMMON 24 VAC HOT EARTH GND CONTROLLER POWE...

Страница 6: ...or point wiring for AI3 DI3 approximately 1 cm from the end 2 Wind the cable tightly twice around the filter 3 Close the filter and wrap it with a zip tie covering wound cable Figure 6 Adding Ferrite Filter s for CE Compliance CAUTION Ferrite filter s must be installed on the room temperature sensor RTS cable and any wiring to AI3 DI3 If not the controller is not CE compliant ...

Страница 7: ... 2 DO 7 NO C DO 8 NO C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 C H GND S E H C Y1 G Y2 CW COMMON CCW COLD DUCT DAMPER ACTUATOR Y1 G Y2 CW COMMON CCW HOT DUCT DAMPER ACTUATOR ELECTRIC HEAT STAGE 2 OPTIONAL OR SPARE DO ELECTRIC HEAT STAGE 1 OPTIONAL OR SPARE DO AVS 2 AUTOZERO MODULE OPTIONAL OR SPARE DO Figure 7 Point Wiring for Applications 2237 2238 2267 and 2268 with Electric Reheat 1 ...

Страница 8: ... 12 13 14 15 16 17 18 19 20 C H GND S E H C Y1 G Y2 CW COMMON CCW COLD DUCT DAMPER ACTUATOR Y1 G Y2 CW COMMON CCW HOT DUCT DAMPER ACTUATOR ELECTRIC HEAT STAGE 2 OPTIONAL OR SPARE DO ELECTRIC HEAT STAGE 1 OPTIONAL OR SPARE DO AVS 2 AUTOZERO MODULE OPTIONAL OR SPARE DO DUCT TEMPERATURE SENSOR 100K THERMISTOR OPTIONAL Figure 9 Point Wiring for Application 2269 with Electric Reheat 1 2 3 4 5 6 7 8 9 1...

Страница 9: ...IL 60089 4513 U S A Your feedback is important to us If you have comments about this document please send them to technical editor sbt siemens com Document No 550 308 Printed in the U S A Page 9 NOTE Record only those points marked with an asterisk on the CIS display Use F3 Look to identify the initial value for each point marked with an asterisk You may want to make extra copies of this table for...

Отзывы: