![Siemens Mobile TC45 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/siemens-mobile/tc45/tc45_manual_1266136039.webp)
TC45 AT Command Set
2.8 AT+CFUN
s
m
obile
TC45_ATC_V02.02
Page 39 of 461
4/16/04
Confidential / Released
Command Description
The test command returns the values of the supported parameters.
The read command returns the current functionality value.
The write command can be used to reset the ME, to choose one of the SLEEP modes or to return to full func-
tionality.
Parameter Description
0
NON-CYCLIC SLEEP mode:
In this mode, the AT interface is not accessible. Consequently, once you have
set
level 0, do not send further characters. Otherwise these characters
remain in the input buffer and may delay the output of an unsolicited result
code.
The first wake-up event stops power saving and takes the ME back to full func-
tionality level
=1.
[1]
(&F)
Full functionality.
If the ME is in one of the CYCLIC SLEEP modes you can issue AT+CFUN=1
to stop power saving and return to full functionality. If the ME is NON-CYCLIC
SLEEP mode,
=1 can also be sent by the Java application.
Keep in mind that, unlike the reset command described below, this action does
not restart the ME but only changes the level of functionality. See parameter
for details on the reset.
5
CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled during paging. If characters
are recognized on the serial interface, the ME stays active for 2 seconds after
the last character was sent or received.
6
CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled during paging.
If characters are recognized on the serial interface, the ME stays active for 10
minutes after the last character was sent or received.
Write Command
AT+CFUN=
[
Response(s)
OK
ERROR
+CME ERROR
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
%
§
§
§
Reference(s)
GSM 07.07
<fun>
(num)