![Siemens Mobile TC45 Скачать руководство пользователя страница 383](http://html.mh-extra.com/html/siemens-mobile/tc45/tc45_manual_1266136383.webp)
TC45 AT Command Set
16.8 AT^SNFA
s
m
obile
TC45_ATC_V02.02
Page 383 of 461
4/16/04
Confidential / Released
Parameter Description
Multiplication factor for input samples. Parameter
is identical with
Formula used to calculate microphone attenuation (negative gain):
Gain in dB = 20 * log(
/32768)
0...32767
(P)
...65535
0
Microphone is muted
32767
No attenuation on the microphone path
Notes
• The command is provided for compatibility with M20 and is a subset of
. The parameter
of
is identical with
• To make the changes persistent use
Example
<atten>
(num)(^SNFW)
^SYSSTART
at^snfa=?
^SNFA: (0-65535)
OK
at^snfa?
^SNFA: 32767
OK
at^snfs=4
OK
at^snfa=1
OK
at^snfa?
^SNFA: 1
OK
at^snfi?
^SNFI: 5,1
OK
at^snfi=5,45
OK
at^snfa?
^SNFA: 45
OK