14
Error
Error
Error
Message Name
Description
Remedy
E001
HEaTERS_DRIVInG_CIRCUIT
The heating plates are over 260 °C
E002
nO_HEaTInG_UP
Heating plates are not heating up
E003
HEaT_UP_TOO_SLOW
Heating plates are heating up too slowly
E004
EEPROM_REaD
Calibration offset is out of the ±100 °C range
E005
COOLInG
Cooling is too slow
E006
TOP_SIDE_HEaTERS
The top side heating plate does not heat up properly
E007
BOTTOM_SIDE_HEaTERS
The bottom side heating plate does not heat up properly
E008
TOP_SIDE_FanS
The top side heating plate does not cool down properly
E009
BOTTOM_SIDE_FanS
The bottom side heating plate does not cool down properly
4.6 Error during heating clamp operation
The heating clamp is equipped with error diagnostics. If an error occurs during operation, an error code appears in
the display.
– When an error occurs, acknowledge it with any button.
Following acknowledgment, the control unit on the device attempts to resume the current mode at the spot in
which the error occurred.
– If the error occurs again: Let the heating clamp cool down completely and restart.
– If the error occurs again: Make a note of the error code, switch the device off and disconnect it from the power supply.
Send the device, including the error code, to Forbo Customer Service for servicing.
allow the heating clamp to cool
down completely and restart.
If the error occurs again:
Send heating clamp including
error message to Forbo
Customer Service.