siegling blizzard HC120/40 Скачать руководство пользователя страница 10

10

4 OPERaTIOn

4.1 Prepare device and workstation

–  Ensure that the workstation is clean and tidy.  

a heat-resistant surface on which to safely place the Siegling Blizzard heating clamp during operation must be available.

 

 

Stop

  The device is not splash-proof. The device is not explosion-proof.
  Operation under improper conditions can lead to serious damage to the device and injury to the operator
  (electric shock, burns, explosion damage).

–  Carefully check the heating clamp and power cable for damage (visual inspection).  

The Siegling Blizzard heating clamp may only be operated if it is in faultless condition. 

 

 

Stop

  Operating a damaged device can cause further damage to the device and result in injury to the user (electric shock,  

burns, crushing, cuts).

–  Ensure that both heating plates are free of dirt and deposits.  

Carefully remove any dirt or deposits by wiping with a clean cloth moistened with ammonia.

 

 

Stop

  Clean heating plates only when cold and do not use flammable cleaning solutions.  

Risk of severe burns and high fire risk!

4.2 Connect to the power supply

 

–  Compare the connection values of your heating clamp to those of the power supply.
–  Only connect to the power supply if the values are the same 230 V / 50 Hz or 115 V / 60 Hz.

 

Caution

Operating the heating clamp with the wrong voltage can cause serious damage to the device. 

 

Caution

avoid connecting the heating clamp to machine sockets.

Potential problem:

 When starting up the machine there is a risk of voltage peaks, 

which may damage the heating clamp electronics.

Action: 

Connect the heating clamp to an on-site power supply.

Содержание HC120/40

Страница 1: ...Siegling total belting solutions User manual Blizzard Heating Clamp HC120 40 Contents 3 English manual 17 Betriebsanleitung siegling blizzard splicing equipment TM...

Страница 2: ...tuoti tik asmenims perskai iusiems ir supra tusiems toliau pateikt voki k arba angli k instrukcij inyn Dit apparaat mag alleen door personen in gebruik worden genomen die de volgende Duitse of Engelse...

Страница 3: ...3 User Manual Blizzard Heating Clamp HC120 40 English Contents 4 General information 5 Safety 6 Description 10 Operation 15 Manufacturer s notification Customer service EC Declaration of Conformity...

Страница 4: ...instructions Please keep it accessible for other users so they may read the instructions prior to using the heating clamp Important instructions are indicated in the text as follows Note This indicat...

Страница 5: ...g clamp must be per formed in accordance with this manual the technical documentation accompanying the machinery when making belts endless in machinery any relevant FMS splicing data sheets all releva...

Страница 6: ...ons in mm and inches in All measurements in inches are rounded Upper heating plate Lower heating plate inserted belt Control unit with digital display and buttons Lower part of heating clamp Lower par...

Страница 7: ...lyurethane No other accessories are required such as an external control unit or cooling clamp The Siegling Blizzard heating clamp is electrically heated and air cooled using fans The heating and subs...

Страница 8: ...e the splicing parameters in setting mode Heating temperature Holding time Cooling temperature Insert the prepared splice guide into the heating clamp Start heating cycle Heating plates are heated to...

Страница 9: ...setting mode and to terminate setting mode or to save the previously entered calibration values in calibration mode and to terminate calibration mode or to terminate heating up mode and start heating...

Страница 10: ...in injury to the user electric shock burns crushing cuts Ensure that both heating plates are free of dirt and deposits Carefully remove any dirt or deposits by wiping with a clean cloth moistened wit...

Страница 11: ...mperature C or F This loop can be repeated as many times as desired Holding down the SELECT button toggles between C and F Pressing the or button changes the value that is displayed Heating temperatur...

Страница 12: ...second Fig 4 4 2 Wait until the heating clamp reaches the selected heating temperature and holds steady duration approx 5 minutes Signal frequency increases to approx 2 3 times per second Insert the...

Страница 13: ...device on the splice guide Fig 4 5 2 Press the CONFIRM button to start heating mode The inserted splice guide and belt are cold That is why the temperature on the display briefly falls and the heating...

Страница 14: ...es not cool down properly 4 6 Error during heating clamp operation The heating clamp is equipped with error diagnostics If an error occurs during operation an error code appears in the display When an...

Страница 15: ...llowing EC directives EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61000 6 1 2007 EN 61335 1 2012 A11 2014 EN 61335 2 45 2002 A1 2008 A2 2012 EN 62233 2008 Forbo Siegling G...

Страница 16: ...16...

Страница 17: ...17 Betriebsanleitung Blizzard Heizzange HC120 40 Deutsch Inhalt 18 Allgemeines 19 Sicherheit 20 Beschreibung 24 Bedienung 29 Kundendienst Herstellerhinweis EG Konformit tserkl rung...

Страница 18: ...th lt Sicherheitsanweisungen Halten Sie es auch f r andere Nutzer griffbereit damit sie es vor Benutzung der Heizzange lesen k nnen Im Text sind wichtige Anweisungen wie folgt gestaltet Hinweis Hier m...

Страница 19: ...g erfolgen mit dieser Anleitung der Technischen Dokumentation der Anlage beim Endlosmachen von B ndern und Riemen in einer Anlage den jeweils relevanten Verbindungsdatenbl ttern von Forbo Movement Sys...

Страница 20: ...teuerung mit Digitalanzeige und Stellkn pfen Heizzangenunterteil Formschuhunterteil Aufh nge sen 2 x Heizzangenoberteil Formschuhoberteil 310 12 2 145 5 7 130 5 2 Hauptma e in mm und Zoll in Alle z ll...

Страница 21: ...ypenbezeichnung Blizzard HC 120 40 Bandbreite maximal mm 40 Banddicke mm 1 3 3 2 Z Verbindungen mm 35 5 75 35 11 5 70 11 5 110 11 5 Heiztemperatur maximal C 210 Gesamtgewicht kg 2 0 Ma e L x B x H mm...

Страница 22: ...lmodus die Verbindungsparameter einstellen und speichern Heiztemperatur Haltezeit Abk hltemperatur Vorbereiteten Formschuh in die Heizzange einlegen Heizzyklus starten Heizplatten werden auf die vorei...

Страница 23: ...und beendet den Einstellmodus oder speichert im Kalibriermodus die vorher eingegebenen Kalibrierungswerte und beendet den Kalibriermodus oder beendet den Aufheizbetrieb und startet den Heizbetrieb od...

Страница 24: ...ervorrufen Stromschlag Verbrennung Quetschung Schnittwunden Sicherstellen dass beide Heizplatten frei von Schmutz und Ablagerungen sind Bei Verunreinigungen Schmutz und Ablagerungen behutsam mit einem...

Страница 25: ...Diese Schleife kann beliebig oft wiederholt werden Jeweils langes Dr cken der Taste SELECT schaltet um zwischen C und F Durch Dr cken der Tasten oder kann der jeweils angezeigte Wert ge ndert werden...

Страница 26: ...erzeugt dann ca 1 x pro Sekunde ein akustisches Signal Abb 4 4 2 Warten bis die Heizzange die gew hlte Heiztemperatur erreicht hat und stabil h lt Dauer ca 5 Minuten Die Signalh ufigkeit erh ht sich a...

Страница 27: ...wird durch die Arretierungsvorrichtung am Formschuh erleichtert Abb 4 5 2 Durch Dr cken der Tasteden Heizmodus starten Der eingelegte Formschuh mit dem Band ist kalt Daher f llt die Temperatur im Disp...

Страница 28: ...rbo Kundenservice einsenden Fehler Fehler Fehler meldung bezeichnung beschreibung Abhilfe E001 REGELKREIS_HEIZUNG Temperatur der Heizplatten ber 260 C E002 KEINE_HEIZLEISTUNG Die Heizplatten erw rmen...

Страница 29: ...erf llt EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61000 6 1 2007 EN 61335 1 2012 A11 2014 EN 61335 2 45 2002 A1 2008 A2 2012 EN 62233 2008 Forbo Siegling GmbH Hannover N...

Страница 30: ...vice points are located in more than 300 places worldwide Committed staff quality orientated organisation and production processes ensure the constantly high standards of our products and services The...

Отзывы: