1
Target group of this documentation
•
This.documentation.is.intended.for.use.by.
specialists.and.end.users.
•
All.instructions.concerning.assembly,.installation.
and.repairs.described.in.this.document.are.to.be.
performed.exclusively.by.experienced.professionals.
with.training.and.practice.in.the.installation,.
commissioning,.servicing.and.maintenance.of.
decentralised.ventilation.units.
•
All.notes.on.operation.and.maintenance.as.well.as.
the.rectification.of.malfunctions.described.here.are.
intended.for.specialists.and.end.users.
•
After.the.successful.assembly.and.installation,.the.
installation.company.is.committed.to.handing.over.
the.operating.instructions.to.the.end.user.
2
Intended use
•
The.
AEROMAT VT RS2
.is.intended.for.installation.in.
the.exterior.windows/walls.of.permanent.structures.
in.accordance.with.our.installation.and.planning.
documents.and.the.specifications.of.our.operating.
instructions.and.is.only.suitable.for.the.ventilation.
of.enclosed.rooms.
•
The.
AEROMAT VT RS2
.must.be.installed.in.the.
intended.installation.position.(horizontal.or.
vertical)..The.intended.installation.position.results.
from.the.weather.grille.preassembled.in.the.factory.
Weather.grille:.911.HW;.installation.position:.horizontal
Weather.grille:.911.HW-g.(concealed.installation.in.the.wall);.
installation.position:.horizontal
Weather.grille:.911.CW;.installation.position:.horizontal
Weather.grille:.911.HS;.installation.position:.vertical
Weather.grille:.911.CS;.installation.position:.vertical
•
Do.not.use.the.
AEROMAT VT RS2 in environments
with.corrosive.or.explosive.atmospheres.(dust,.
vapour.or.gas).
•
Do.not.install.the.unit.in.contaminated.rooms.and.
ensure.that.no.hazardous.substances.can.be.drawn.
in.
•
The.
AEROMAT VT RS2
.may.be.installed.in.damp.
locations.in.protection.class.2;.however,.the.socket.
used.must.be.in.at.least.protection.class.3.
•
If.the.
AEROMAT VT RS2
.is.to.be.used.in.a.room.with.
a.heating.unit.that.draws.air.from.the.room,.prior.
authorisation.must.be.obtained.from.the.proper.
authorities,.such.as.the.officially.appointed.district.
chimney.sweep.
•
Only.operate.and/or.store.the.
AEROMAT VT RS2 at
temperatures.between.‒.15.°C.and.+40.°C.
•
Use.the.
AEROMAT VT RS2
.only.with.genuine.
accessories.from.SIEGENIA.
•
Use.the.
AEROMAT VT RS2
.only.when.it.is.in.a.
technically.sound.condition.
•
Do.not.modify.the.unit's.components.in.any.way.
•
Ensure.that.the.ventilation.openings.are.kept.free.
and.are.not.blocked.by.other.equipment,.furniture.
or.objects.
•
Please.do.not.put.any.objects.on.top.of.the.unit.