03.2021
10/20
H47.FENS083EN-02
AERO
Original operating instructions
AEROMAT VT RS2
7
Mains supply
Depending.on.the.design,.the.
AEROMAT VT RS2 is
connected.to.a.suitable.socket.of.the.230-V.AC.mains.
power.supply.using.the.Euro.plug.or.directly.to.the.
230-V.AC.mains.power.supply.using.an.external.switch.
7.1
Socket connection
When.installed.in.damp.rooms,.the.socket.for.the.
AEROMAT VT RS2 must be installed in at least
protection.class.3.
7.2
External switch connection
WARNING
Exposed.electrical.components
Risk of fatal injury from electric shock or fire
•
Work.on.a.230.V.AC.mains.power.supply.may.only.be.
performed.by.a.qualified.electrician.
•
All.work.on.the.230.V.AC.mains.power.supply.must.be.
carried.out.in.compliance.with.the.current.German.VDE.
regulations.(e..g.,.VDE.0100).and.any.relevant.country-
specific.requirements.
•
Switch.off.or.unscrew.the.security.devices.
If.the.
AEROMAT VT RS2
.is.connected.directly.to.the.
230.V.AC.mains.power.supply,.the.customer.must.
install a mains isolator
7.3
Wiring diagram series switch
L1
N
18
17
16
15
13
11
10
9
8
7
14
12
6
5
4
3
2
1
4
3
2
1
S1
S2
Le
vel 1
Flat.ribbon.cable
20 V DC
20 V DC
red
black
yellow
red
black
yellow
Supply.air.+
Supply.air.-
Exhaust.air.+
Exhaust.air.-
+.
24
.V
butt
on
butt
on
butt
on
Le
vel 2
Le
vel 1
Inputs
Blo
w
er
Supply
.air
Exhaus
t.
air
Slider
Tr
ans
-
former
Transformer
Le
vel 2
Le
vel 3
black
gr
ey
blue
br
own
Switch
Value
Colour
S1
Blower level 1
black
S2
Blower level 2
grey
8
Unit function
8.1
Ventilation with blowers
•
The.
AEROMAT VT RS2
.is.equipped.with.2.blowers.
•
Supply.air.fan.(depending.on.the.the.equipment):.
the.outside.air.is.drawn.in.through.the.supply.air.fan.
and.enters.the.room.as.supply.air.
•
Exhaust.air.blower.(depending.on.the.equipment):.
the.exhaust.air.is.drawn.in.through.the.exhaust.air.
blower.and.makes.its.way.outside.as.outgoing.air.
•
When.the.blower.is.switched.off,.the.
AEROMAT VT RS2
functions.as.a.pressure.differential.ventilator.
8.2
Ventilation without blowers
•
The.room.is.ventilated.through.air.pressure.
compensation.of.the.indoor.and.outdoor.air.
(pressure.differential)..As.this.happens,.the.air.
normally.flows.into.the.room.from.outside.
•
The.air.flow.into.the.room.varies.as.the.wind.
pressure.changes.with.the.weather.
•
With.the.optional.internal.electrical.closer.(optional),.
the.unit.is.opened.and.closed.using.e.g..an.external.
switch.