Siegenia AERO AEROMAT VT RS2 Скачать руководство пользователя страница 1

ORIGINAL OPERATING 

INSTRUCTIONS

AERO

Sound absorbing ventilator.

AEROMAT VT RS2

Window systems
Door systems
Comfort systems

Содержание AERO AEROMAT VT RS2

Страница 1: ...ORIGINAL OPERATING INSTRUCTIONS AERO Sound absorbing ventilator AEROMAT VT RS2 Window systems Door systems Comfort systems...

Страница 2: ......

Страница 3: ...KEY AND LED DISPLAY 11 9 1 Operating status 11 9 2 Filter replacement indicator 11 10 OPERATION 11 10 1 Adjustment of the blower level using the membrane key 11 10 2 Adjustment of the blower level us...

Страница 4: ...ion results from the weather grille preassembled in the factory Weather grille 911 HW installation position horizontal Weather grille 911 HW g concealed installation in the wall installation position...

Страница 5: ...it Risk of fatal injury from electric shock or fire To prevent personal injury or damage to property always comply with the following instructions Work on a 230 V AC mains power supply may only be per...

Страница 6: ...ginal operating instructions item 2 Quick start instructions SIEGENIA Comfort app item 3 Function 2 exhaust air fans 2 supply air fans or 1 exhaust air fan and 1 supply air fan Membrane key optional G...

Страница 7: ...ition from which the outdoor air is drawn in must be selected in such way that any nearby emission sources have as little impact as possible on the quality of the air being drawn in The maximum permis...

Страница 8: ...nstallation of the exterior insulation or cladding According to the installation location it is thereforenecessarytoadheretheAEROMATVTRS2 at points where rain could permeate AEROMAT VT Film Adhesive t...

Страница 9: ...ENIA aluminium mounting angles AEROMAT VT RS2 with 911 CW weather grille AEROMAT VT RS2 with 911 HW weather grille Dimension Meaning a Assembly area for bracket b Screw and drilling area e g for wall...

Страница 10: ...0 9 8 7 14 12 6 5 4 3 2 1 4 3 2 1 S1 S2 Level 1 Flat ribbon cable 20 V DC 20 V DC red black yellow red black yellow Supply air Supply air Exhaust air Exhaust air 24 V button button button Level 2 Leve...

Страница 11: ...st the required blower level using either the membrane key or the external switch Following a power failure the AEROMAT VT RS2 switches to the last level to be used 10 1 Adjustment of the blower level...

Страница 12: ...ains power supply switch off all poles of the feeder 11 1 Cleaning When cleaning the AEROMAT VT RS2 do not allow any liquid to get inside the unit Never use cleaning agents that are aggressive or cont...

Страница 13: ...tally The number and position of the components can deviate from the figure Be sure to note the arrangement of the internal parts for special models that do not correspond to the figure 1 2 3 4 1 Open...

Страница 14: ...ove the foam 7 Remove the supporting plate to do this press the top toward the interior of the unit and pull out of the bottom 8 Open the transformer compartment and release the blower cable from the...

Страница 15: ...wer supply defective Have the supply voltage checked by a qualified electrician AEROMAT VT RS2 smart does not respond to smartphones tablets No WIFI connection to the router of the home network Restar...

Страница 16: ...15 W Supply voltage 230 V DC 50 Hz Unit operating voltage 24 V AC Protection class II Thermal protection in transformer Max permissible area load per linear metre of ventilator length 1 000 kg Permis...

Страница 17: ...iency h Maximum flow rate 79 m h i Electrical input power 15 W j Noise level 40 dB A k Relative air flow rate 79 m h l Relative pressure differential m Specific input power 0 19 W m h n Control factor...

Страница 18: ...ctive EN 60335 1 2012 A11 2014 EN 62233 2008 c 2014 53 EC RED Directive c1 Electromagnetic compatibility EN 301489 1 V 1 9 2 EN 301 489 17 V 2 2 1 EN 61000 3 2 2014 EN 61000 3 3 2013 c2 Electrical saf...

Страница 19: ......

Страница 20: ...H47 FENS083EN 02 www siegenia com...