A.
PRESSURE DROP (new installation)
1.
Inadequate water supply.
Adjust water regulator on intake (turn screw downward). Increase water
supply to 30 P.S.I. minimum.
2.
Improper nozzle size.
Consult manufacturer.
3.
Open solution injector.
Close injector solution supply valve when not in use
.
B.
PRESSURE DROP AFTER MACHINE IS IN SERVICE
1 Unloader cup or wall scored or worn.
Install a rebuild kit or replace unloader.
2.
Pump piston cup worn.
Install rebuild kit.
3.
Damaged piston cylinders.
Install water sand filter.
4.
Worn nozzle.
Replace with correct or same size nozzle.
5.
Air leak to solution injector.
Close solution injector supply valve or replace hose.
6.
Loose pump drive belt (if applicable).
Adjust tension to achieve ½” movement of belt at mid-point.
7.
Clogged pick-up in tank.
Clear clog.
C.
PULSATION IN HOSE (usually accompanied by a drop in pressure).
1. Open solution injector.
Close solution injector supply valve or fill solution tank.
2. Water supply shortage or clogged pick-up in tank.
Increase pump water supply, clear clogged pick-up..
Clean filter inside pressure regulator or screen in intake connection.
3.
Defective piston cup.
Replace piston cups.
4.
Stuck unloader piston
5.
Obstruction in nozzle causing “false” unloader functions.
TROUBLESHOOTING
22
Содержание 7500S
Страница 2: ......
Страница 17: ...GOLDEN EAGLE 7100 UNLOADER 800 2000 PSI 15 ...
Страница 18: ...16 ...
Страница 19: ...17 ...
Страница 20: ...18 ...
Страница 21: ...19 ...
Страница 34: ...CD6 CD5 CD4 CD3 CD2 CD1 CD13 CD10 CD9 CD8 CD7 CD15 CD14 CD26 CD11 CD12 32 ...
Страница 35: ...CD20 CD19 CD18 CD17 CD16 CD24 CD23 CD22 CD21 CD25 CD15 CD28 CD27 CD29 CD30 33 ...