Siebert SX602 series Скачать руководство пользователя страница 22

 

BAL SX602 PFN RT  

22/36 

The command 

$F1

 activates the flashing of the entire display [33]. The command 

$F0

 deactivates 

the flashing of the entire display [34]. 

Flashing of the entire display can also be activated with an H-signal at function input F2 (priority over 
commands). 

Pos :  66 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Betriebsart en/ di v.  Kapit el:   Anst euer ung,  Betriebs art  dynamisc he T ext e,  Betriebs art  dynamisc he  und s tatische T ext/SX502  Lauf schrif t D VN,  ETH, ETH/I P, IBSPD G WY,MDB,MD B TC P,  MDBTC PG WY,  PFB,  PFN IRT ,  PFN RT ,  SER  s. u.  @  0\ mod_1322820014294_48. doc x  @  3817 @  2 @  1 

 

Marquee text 

Marquee text display is activated from the current position in the text with the 

$Y

 command [9]. It 

remains active up to the end of the text or a forced line break (

$C

). 

If a seven pixel-high font is currently selected, e.g. Acala 7, marquee text activation only affects the 
current line. 

Pos :  67 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Betriebsart en/ di v.  Kapit el:   Anst euer ung,  Betriebs art  dynamisc he T ext e,  Betriebs art  dynamisc he  und s tatische T ext/SX502 Z eilenumbruch DVN ,ETH ,ETH/ IP,I BSPDG WY,MDB,MDB TCP,MDBTC PG WY, PFB, PFN  IR T,PFN RT ,SER s .u. @  0 \ mod_1322820334267_48. doc x @  3822 @  2  @  1 

 

Forced line break 

If the text contains more characters than can be displayed in one line, a line break is inserted 
automatically at the end of the line, and the text is continued in the next line. 

A line break can also be forced at a certain place in the text, for example for correct hyphenation [6] 
using the command 

$C.

 

Pos :  68 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Betriebsart en/ Betriebsart  'Dynamische  und st atisc he T ext e'/Zeic hens atz /SX602 Z eic hens atz  PFN RT  @  3\mod_1465984885565_48.doc x @  26012 @  2 @  1 

 

Character set 

The texts are displayed with the character set specified in menu item 22 as standard (see Chapter 11). 
To call up another character set, one of the 

$M1

 to 

$M5

 commands must be contained in the text [10 

– 

15]. 

Using commands 

$M1

 to 

$M2

 the permanently installed character sets of Acala 7 [10] and Acala 7 

extended [11 are called up. 

A user-defined character set with a character height of seven pixels can be called up with the 
command 

$M5

 [14]. The Acala 7 P character set is preinstalled here. It can be replaced by a character 

set created by the user, for example. 

The optional character sets and the PC-Tool 'FontManager' for generating user-defined character sets 
are included on data carrier. The tool is also used to install the character sets, to save character sets 
on data carrier and to readout installed character sets. 

Pos :  69 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Betriebsart en/ di v.  Kapit el:   Anst euer ung,  Betrie bs art  dynamisc he T ext e,  Betriebs art  dynamisc he  und s tatische T ext/LED-F arbe SX502 D VN, ETH, ETH/I P,  I BSPDG WY,MDB,MDBTC P,MD BTCPG WY,PF B, PFN IR T,PFN RT,SER s .u.  @ 0 \ mod_1322821462814_48. doc x @  3832 @  2  @  1 

 

LED color 

Units with switchable LED color (see Chapter 5) display the texts in red by default. For a color change, 
the command 

$A0

 (red), 

$A1

 (green) or 

$A2

 (orange) must be contained in the text [16...18]. 

Pos :  70 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Betriebsart en/ di v.  Kapit el:   Anst euer ung,  Betriebs art  dynamisc he T ext e,  Betriebs art  dynamisc he  und s tatische T ext/Uhrz eit /Datum  ei nfüg en SX502 D VN, ETH,ETH/I P,I BSPD GWY,MD BTC P,MDB,MDBTC PG WY, PFB,PFN  IRT, PFN RT, SER s. u  @  0\ mod_1322821747882_48. doc x  @  3837 @  2 @  1 

 

Inserting time/date 

The units have a real-time clock with a date and weekday display. The current time, date or parts of 
them can be inserted into the text with the 

$H...

 and 

$D...

 commands [20 

– 30]. The year can be 

displayed with four [24, 28] or two [25, 29] digits]. 

The day of the week is displayed abbreviated to two letters in the language set in menu item 23. 

Pos :  71 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Betriebsart en/ di v.  Kapit el:   Anst euer ung,  Betriebs art  dynamisc he T ext e,  Betriebs art  dynamisc he  und s tatische T ext/Bargraph D VN, ETH, ETH/ IP,IBSPDG WY,MDB,MDBTC P,MD BTCPG WY, PF B, PFN IRT ,PFN  RT, SER s.u.  @ 0 \ mod_1318503443139_48. doc x  @ 3129 @  2  @  1  

 

Bar graph 

The 

$Gnnnn

 command in the data telegram is used for activating the bar graph. [31]. 

nnnn

 stands for 

the number luminous columns, i.e. the length of the bar graph and must always be four digits, p. e. 
$G0040. 

Units with switchable LED color (see Chapter 5) can only show the Bar graph in red or green. In bar 
graph mode they ignore command 

$A2

 for the color orange. [18]. 

Pos :  72 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Betriebsart en/ di v.  Kapit el:   Anst euer ung,  Betriebs art  dynamisc he T ext e,  Betriebs art  dynamisc he  und s tatische T ext/Z eichen $ SX502 D VN, ETH, ETH/I P,  IBSPD G WY,MDB,MDBTC P,MD BTCPG WY, PF B, PFN IRT ,PF N RT,SER s .u. @  0 \ mod_1318503648466_48. doc x @  3134 @  2  @  1 

 

Character $ 

The command for displaying the character '$' is 

$$

 [32]. 

Содержание SX602 series

Страница 1: ...erie SX502 SX602 Titelseiten SX602 PFN RT 3 mod_1465903296097_48 docx 25854 1 Series SX602 Alphanumeric large size displays with Profinet IO RT interface Operating instructions Pos 3 Siebert Seitenumb...

Страница 2: ...roup com FRANCE Siebert France Sarl 4 rue de l Abb Louis Verdet F 57200 Sarreguemines P O Box 90 334 F 57203 Sarreguemines C dex Phone 33 0 3 87 98 63 68 Fax 33 0 3 87 98 63 94 email info fr siebert g...

Страница 3: ...siebert group com Siebert LRD and XC Board are registered trademarks of Siebert Industrieelektronik GmbH All other product names mentioned herein may be trademarks or registered trademarks of their re...

Страница 4: ...tion 9 Unit construction 9 Principle circuit diagram 10 Central Processing Unit 11 Profinet IO interface 11 Serial Interface 11 Function inputs 12 Menu display 12 Status indicators 12 Battery 13 Power...

Страница 5: ...types 19 Commands 19 Table of commands 19 Display dynamic text 21 Static texts 21 Inserting variables 21 Deleting text 21 Flashing 21 Marquee text 22 Forced line break 22 Character set 22 LED color 22...

Страница 6: ...aracter table 28 13 Technical data 29 Unit properties 29 Housing colors 29 Front frame 29 Ambient conditions 30 Max power consumption 30 Screw type terminals 30 Fixed text memory 30 Marquee 30 Real ti...

Страница 7: ...ns The repair and replacement of components and modules may only be carried out by the manufacturer for safety reasons and due to the required compliance with the documented unit properties The units...

Страница 8: ...o prevent interference This applies especially to unshielded operating voltage cables Shielded cables are also to be kept short due to any interference which might be emitted by the shielding Neither...

Страница 9: ...r tebeschrei bung Ger teaufbau SX602 Ger teaufbau PFN RT 3 mod_1465903805669_48 docx 25867 2 1 Unit construction The following figure shows model type SX602 10 10 xx xxx xx xx as example for the other...

Страница 10: ...BAL SX602 PFN RT 10 36 Principle circuit diagram Central Processing Unit Power supply unit Power supply Display Battery Sub D connector serial interface Function input Status indicato...

Страница 11: ...ungen Seri e SX502 SX602 Ger tebeschrei bung Schnittstellen Seriell Serielle Schni ttstelle SX502 ETH IP IBSPDGWY MDBTC P MD BTCPGWY DVN PFB PFN RT SX602 PFN RT 2 mod_1408019069537_48 docx 9211 2 1 Se...

Страница 12: ...he following status messages may appear on the menu display The display was not assigned with a name yet The display was not assigned with an IP address yet Display is ready for Profinet In programmin...

Страница 13: ...SX502 DVN ETH ETH IP MD B IBSPDGWY MDBTC P MD BTCPGWY PFB PFN IRT s u 2 mod_1408356423444_48 docx 9487 2 1 Battery The lithium battery type CR2032 provides a power reserve for the real time clock It...

Страница 14: ...eichendarstellung SX602 Propor tionalschrift PFN RT 3 mod_1465908678786_48 docx 25954 2 1 Proportional lettering The character sets Acala 7 and Acala 7 extended display the characters in non proportio...

Страница 15: ...Pos 35 Si ebert Bedi enungsanlei tungen Seri e S302 SX302 SX502 SX602 berei nsti mmung en Konfigurati on Gr ossanzeigen brei nsti mmung versch Serien GSDM L Datei SX502 SX602 GSDML D atei PFN RT 2 mod...

Страница 16: ...SX602 PFN RT 0 mod_1322732081577_48 docx 3663 1 The units can display dynamic and static texts Dynamic texts can be changed while the unit is running They are generated from within the process and hav...

Страница 17: ...2 PFN R T 2 mod_1408024333166_48 docx 9383 2 1 Input Output data bytes The number of output data bytes is fixed on two Pos 45 Si ebert Bedi enungsanlei tungen Seri e SX502 SX602 Betriebsarten Betriebs...

Страница 18: ...ng settings have to be made in the menu Pos 53 Si ebert Bedi enungsanlei tungen Seri e SX502 SX602 Betriebsarten Betriebsart Dynamische und statische Texte Daten bertragung D aten bertr agung SX502 PF...

Страница 19: ...y are generated from within the process and are sent to the display via the PROFINET interface Static texts cannot be changed while the unit is running They are compiled using the PC tool Display Mana...

Страница 20: ...ting date DA Current date four digit year TT MM JJJJ 24 DB Current date two digit year TT MM JJ 25 DD Current day TT 26 DM Current month MM 27 DY Current year four digit JJJJ 28 DZ Current year two di...

Страница 21: ...to the display and subsequent insertion of just the appropriate characters variables to update the variable text components In the example shown above the fixed text components of temperature expansio...

Страница 22: ...mple The optional character sets and the PC Tool FontManager for generating user defined character sets are included on data carrier The tool is also used to install the character sets to save charact...

Страница 23: ...FN RT SX602 PFN RT 2 mod_1398435994717_48 docx 8124 2 1 Setting time date Setting of the time is done with the command SHhhmmss 38 hh stands for hours mm for minutes and ss for seconds p e SH204515 20...

Страница 24: ...and keep it pressed Next setting Shortly press key Page settings forward Press key long Previous setting Double click on key Page setting backward Double click on key and keep it pressed To exit the m...

Страница 25: ...95 Setting time minutes 0 59 99 Save Save parameters Set Not saving parameters Escape Restore to factory settings Default Pos 87 Si ebert Bedi enungsanlei tungen Seri e SX502 SX602 Par ametrierung Be...

Страница 26: ...an be loaded with the setting It can be replaced by a user defined character set with a character height of up to 7 pixels The optional character sets and the PC tool FontManager for creating user def...

Страница 27: ...FB PFN IR T PFN RT SER bis4 02 SX602 PFN RT 2 mod_1408021326172_48 docx 9307 2 1 Fault messages Serious faults due to improper operation or faulty operating conditions are indicated in the display The...

Страница 28: ...U 149 213 22 _ 86 V 150 214 23 87 W 151 215 24 88 X 152 216 25 89 Y 153 217 26 EOF 90 Z 154 218 27 ESC 91 155 219 28 92 156 220 29 93 157 221 30 94 158 222 31 95 _ 159 223 32 SPACE 96 160 224 a 33 97...

Страница 29: ...entry point from the bottom 0 Wall mounting cable entry point from the top 1 Hanging installation cable entry point from the bottom 2 Hanging installation cable entry point from the top 3 Wall mountin...

Страница 30: ...SX602 06 25 0M 2xx xx xx ca 400 VA SX602 08 25 0R 1xx xx xx ca 180 VA SX602 08 25 0R 2xx xx xx ca 350 VA SX602 08 25 0M 1xx xx xx ca 270 VA SX602 08 25 0M 2xx xx xx ca 530 VA For units with built in h...

Страница 31: ...SX602 20 05 0x 1xx xx xx representing the other unit versions listed in the following table All dimensions are in mm 70 70 a 250 70 130 45 20 20 20 20 9 Unit version a Weight SSX602 20 05 0x 1xx xx x...

Страница 32: ...20 05 0x 2xx xx xx representing the other unit versions listed in the following table All dimensions are in mm 70 70 30 a 250 70 30 210 45 45 Unit version a Weight SX602 20 05 0x 2xx xx xx 1040 appro...

Страница 33: ...in mm 20 20 20 20 45 130 a 70 70 70 b 9 Unit version a b Weight SX602 04 16 0x 1xx xx xx 670 300 approx 13 kg SX602 06 16 0x 1xx xx xx 960 300 approx 18 kg SX602 08 16 0x 1xx xx xx 1240 300 approx 22...

Страница 34: ...are in mm 210 45 45 a 30 70 70 70 30 b Unit versions a b Weight SX602 04 16 0x 2xx xx xx 670 300 approx 22 kg SX602 06 16 0x 2xx xx xx 960 300 approx 28 kg SX602 08 16 0x 2xx xx xx 1240 300 approx 34...

Страница 35: ...tion grates on units ventilated by other means The ventilation grates and their arrangement are not pictured to scale The following table specifies the ventilation grates of the individual unit versio...

Страница 36: ...d by other means The ventilation grates and their arrangement are not pictured to scale The following table specifies the ventilation grates of the individual unit versions Unit version b c LG1 LG2 LG...

Отзывы: