5
SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T
-
SRL(P)100/185T
1.0.5 - Sept. 2014
TYPE
SRV/SRL
Thruster med en hastighet
TYPE
SRVP/SRLP:
Thruster med regulerbar hastighet
Motor:
Spesialutviklet reversibel DC-motor.
Girhus:
Sjøvannsbestandig bronsje. Kulelagre på propellaksel.
Kule og glidelager komb. på drivaksel.
Galvanisk isolert fra motor
Tunnel:
Glssfiberforsterket polyamid
Propell:
5-blads skew "Q"-propell i komposittmateriale.
Batterier:
Minimum anbefalt batteri størrelse.
(Kaldstart kapasitet etter DIN/SAE std.)
SRV(P)80/185T 12V : 550 CCA DIN/1045 CCA SAE
SRV(P)80/185T 24V : 300 CCA DIN/570 CCA SAE
SRV(P)100/185T 12V : 750 CCA DIN/1445 CCA SAE
SRV(P)100/185T 24V : 400 CCA DIN/760 CCA SAE
SRL(P)80/185T 12V : 550 CCA DIN/1045 CCA SAE
SRL(P)80/185T 24V : 300 CCA DIN/570 CCA SAE
SRL(P)100/185T 12V : 750 CCA DIN/1445 CCA SAE
SRL(P)100/185T 24V : 400 CCA DIN/760 CCA SAE
Driftstid:
S2 = 3 min. eller gjennomsnittlig 7-10% innen en beg
-
renset tidsperiode.
(Faktisk driftstid vil variere med ventilasjon, mon-
teringsdybde og faktisk tilført spenningsnivå til
thrusteren)
Sikkerhet:
Elektronisk tidsforsinkelse forhindrer motorskade ved
rask retningsendring. Motoren stanser automatisk ved
overopphetning (slår seg automatisk på etter ned-
kjøling).Fleksibel kobling mellom drivaksel og motor
beskytter elektromotor og gir hvis propell blir blokkert.
Etter siste kjøring av thrusteren vil en forhåndsinnstilt
tid i panelet (avhengig av paneltype) slå av dette og
felle inn thrusteren.
Trusteren vil automatisk felles inn når panelet slås
av (manuelt eller automatisk)
Integrert microprossessor føler hele tiden på reléet,
reduserer slitasje og risk for ”heng” på relé. Trusteren
vil stoppe automatisk om det oppstår ”heng” på reléet.
TYPE
SRV/SRL
Thruster with one speed
TYPE
SRVP/SRLP:
Thruster with speed control
Motor:
Custom made reversible DC-motor.
Gearhouse:
Seawater resistant bronze. Ballbearing at
propellershaft and combination of ballbearing and slide
bearing at driveshaft. Galvanically separated from the
motor.
Tunnel:
Fibreglass reinforced polyamid
Propeller:
5 blade skew "Q"-propeller,
fibreglass reinforced composite.
Batteries:
Minimum recommended battery capacity
(cold crank capacity by DIN/SAE standard)
SRV(P)80/185T 12V : 550 CCA DIN/1045 CCA SAE
SRV(P)80/185T 24V : 300 CCA DIN/570 CCA SAE
SRV(P)100/185T 12V : 750 CCA DIN/1445 CCA SAE
SRV(P)100/185T 24V : 400 CCA DIN/760 CCA SAE
SRL(P)80/185T 12V : 550 CCA DIN/1045 CCA SAE
SRL(P)80/185T 24V : 300 CCA DIN/570 CCA SAE
SRL(P)100/185T 12V : 750 CCA DIN/1445 CCA SAE
SRL(P)100/185T 24V : 400 CCA DIN/760 CCA SAE
Max. use:
S2 = 3 min. or appr. 7-10% within a limited time frame.
(The actual duty time will vary - depending on
ventilation level, depth of thruster and actual
delivered voltage to thruster)
Safety:
Electronic time-delay device protects against sudden
change of drive direction. Electric thermal cut-off switch
in electromotor protects against over heating (auto
reset when electro motor cools down). Flexible coupling
between electro-motor and driveshaft protects
electromotor and gearsystem if propeller gets jammed.
After a preset time in the panel(depending on panel
model), the panel will turn off, and the thruster will
retract.The thruster will automatically retract when the
panel is turned off (manual or automatic)
Integrated microprocessor monitors solenoids,
reducing wear and risk of solenoid lock-in. Auto-stop of
thruster in case of accidental solenoid lock-in.
Technical specifications
EN
Tekniske spesifikasjoner
NO
Min. 185mm
WATERLINE
Fig. 1
Содержание SEP 80/185 T
Страница 29: ...29 SRV P 80 185T SRL P 80 185T SRV P 100 185T SRL P 100 185T 1 0 5 Sept 2014 Notes ...
Страница 30: ...30 SRV P 80 185T SRL P 80 185T SRV P 100 185T SRL P 100 185T 1 0 5 Sept 2014 Notes ...
Страница 31: ...31 SRV P 80 185T SRL P 80 185T SRV P 100 185T SRL P 100 185T 1 0 5 Sept 2014 Notes ...