FAULT INDICATORS
8
Fault indicators
8.1
LED fault indicators
PWR
RUN
COM
ERR
Description
X
flashes
acyclically
–/X
X/flashes
acyclically
No communication with bus
devices or serious fault
X
–(100 ms) –/X
X/flashes
acyclically
Fault has occurred
X
–/flashes
acyclically
–/X
X
Incorrect configuration
X
–/X
–
flashes
cyclically
No communication with DP master
Table 2:X: on, –: off
8.2
Error codes
8.2.1
Diagnostic faults for the WI180C-PB
Error code
Description
0x06
Number of connected bus devices was reduced
0x09
Different number of registered and actually connected bus devices
0x0A
Timeout during communication with bus device
0x0B
Internal communication fault
0x0C
Unexpected response from internal bus