Signal converter SK 20.2
24
2.3 Outputs
2.3.1 Digital transistor output:
Active
= ready
Non active
= error or programming mode
2.3.2 Analogue output (resolution 16 bit) selectable:
0 - 10 V
0 - 20 mA
4 - 20 mA
•
By changing "min" and "max" positions the analogue output operates
inverse.
Figure 2: Correlation Position - Analogue output
•
In "min" position the analogue output is 0 V (0/4 mA).
•
In "max" position the analogue output is 10 V (20 mA).
•
Positions between "min" and "max" will be converted in analogue signal
with a
16 bit resolution.
•
The positions "min" and "max" are programmable by teach in function.
10 V (20 mA)
10 V (20 mA)
0 V (4 mA)
0 V (4 mA)
analog signal
max
min
position
position
min
max
8026616/2021-03-11 • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com