MOUNTING INSTRUCTIONS
4.3
safeRS Control safety outputs terminal block
Symbol
Description
COM
Common safety output 1
NO
Relay output normally open
COM
Common safety output 2
NO
Relay output normally open
Note
: the operating temperature of the cables must be at least 105 °C.
Note
: use only copper wires with a minimum gauge of 18 AWG and a torque of 0.56 Nm
(5 lbs in).
4.4
safeRS Control auxiliary outputs terminal block
Symbol
Description
COM
Common auxiliary output 1
NO
Relay output normally open
COM
Common auxiliary output 2
NO
Relay output normally open
Note
: the operating temperature of the cables must be at least 80 °C.
Note
: use only copper wires with a minimum gauge of 18 AWG and a torque of 0.56 Nm
(5 lbs in).