o p t o - e L e c t r o n i c p r o t e c t i v e d e v i c e S | S i c K
8014476/2012-09-19
Subject to change without notice
Safety laser scanners
8
S300 Mini
Electrical data
S300 Mini Standard
S300 Mini remote
connection type
Connecting cable with round plug connector
connecting cable length
250 mm
diameter of round plug connector
15 mm
Supply voltage v
s
24 V DC (16.8 V DC ... 30 V DC)
power consumption
≤ 0.25 A (24 V DC)
1)
≤ 1.35 A (24 V DC)
2)
universal i/os
2
–
number of inputs
Static control inputs (with EFI)
External device monitoring (EDM)
Restart/reset
Standby
–
1
3)
1
3)
1
3)
5
4)
–
–
1
4)
number of outputs
Reset required
Safety outputs (OSSD)
Output for warning field
-
1
3)
2
2
3)
Depends on the configuration of the
connected EFI device
–
–
–
configuration and diagnostics interface
Transmission rate
RS-232
38.4 kBaud
Safe device communication via efi/SdL
Transmission rate
Cable length
Galvanized decoupling
–
–
–
≤ 500 kBaud
20 m
5)
–
1)
Without output load.
2)
Including maximum output load.
3)
Availability depends on the configuration of the universal I/Os.
4)
The S300 Mini Remote can only be operated on an S3000/S300 safety laser scanner, on a safety controller Flexi Soft or on a sens:Control device via EFI.
5)
Use only pre-assembled extension cables.
ordering information
Delivery S300 Mini
•
Safety laser scanner
•
Operating instructions and CDS (Configuration & Diagnostic Software) on CD-ROM
•
Adhesive label “important information”
The extension cable has to be ordered separately!
designation
protective field range
Model name
part no.
S300 Mini Standard
2 m
3 m
S300 Mini Remote
2 m
3 m