A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
o p t o - e L e c t r o n i c p r o t e c t i v e d e v i c e S | S i c K
8014476/2012-09-19
Subject to change without notice
Safety laser scanners
7
S300 Mini
detailed technical data
You can find more detailed data in the operating instructions. Download at www.mysick.com.
General data
Laser protection class
1 (CFR 1040.10 and 1040.11, CDRH 21, IEC 60825-1)
enclosure rating
IP 65 (EN 60529)
protection class
III (EN 50178 and EN 60950)
Safety-related parameters
Type
Safety integrity level
Category
Performance level
PFHd (mean probability of a dangerous failure
per hour)
T
M
(Mission Time)
Type 3 (EN 61496-1)
SIL2 (IEC 61508), SILCL2 (EN 62061)
Category 3 (EN ISO 13849)
PL d (EN ISO 13849)
8.0 x 10
-8
(EN ISO 13849)
20 years (EN ISO 13849)
ambient operating temperature from ... to
–10 °C ... +50 °C
type of light
Pulsed laser diode
Wave length
905 nm
Housing color
RAL 1021 (yellow), RAL 9005 (black)
Housing material
Die-cast aluminum
front screen material
Polycarbonat
front screen surface finish
Outside with scratch-resistant coating
dimensions (W x H x d)
102 mm x 116 mm x 105 mm
Weight
0.8 kg, without connecting cables
Functional data
S300 Mini Standard
S300 Mini remote
Scanning angle
270°
protective field range, radial
2 m / 3 m (depending on type)
number of field sets
1
16
type of field sets
Triple field sets with 1 protective field and 2 warning fields each
number of monitoring cases
1
32
remission
1.8 % ... > 1,000 %, reflectors
response time
80 ms
resolution
30 mm, 40 mm, 50 mm, 70 mm, selectable
30 mm, 40 mm, 50 mm, 70 mm, 150 mm, selectable
(depending on type)
angular resolution
0.5°
protective field supplement
100 mm
Warning field range
8 m
distance measuring range
30 m
number of multiple samplings
2 ... 16, configurable via CDS
delay of automatic reset
2 s ... 60 s, configurable