Technical information
RFU6xx FB for
GX Works 2 (PNDP)
Page 10
Parameter
Declara-
tion
Data type
Description
Mode_UII
Input /
Output
Word
[Signed]
(0..15)
Transponder Identification (UII) in a hexa-
decimal format.
The length of the UII must be defined by the
Mode_UIILength parameter.
The UII is automatically determined in
the Single-Tag mode and does not have
to be assigned.
Example:
UII (hex)= 1234 0000 0000 0000 0000 0002
Mode_RSSI
Output
Word
[Signed]
(0..3)
Outputs the RSSI values (reception
strength) of the transponder in the reading
field (only in Mode 1).
[1] = RSSI value from antenna 1 (internal)
[2] = RSSI value from antenna 2 (external)
[3] = RSSI value from antenna 3 (external)
[4] = RSSI value from antenna 4 (external)
Table 1: Mode parameters