Operating Instructions
Chapter
10
RFI341
8013171/ZO93/2017-08-08
©
SICK AG
•
Germany
•
All rights reserved
41
Appendi
x
6.4.3 Permanently load changed parameter sets into the device
Changed parameter values are immediately transferred to the RFH620 main memory
(RAM) depending on the option (“Immediate download“). To ensure that the changes
remain even after the bar code scanner is restarted, the configuration has to be
permanently saved in the RFH620's PROM.
¾
In order to load the current settings permanently in the bar code scanner, select the
command PARAMETER/SAVE PERMANENT in the menu bar under CLV62X or
click on “save” in the tool bar
6.4.4 Save, display and print the current parameter set
When archiving a parameter set it is recommended to not only save the project file on
the PC but also print out the contents of the file.
1. In order to save the current parameter set, select the menu item SAVE PROJECT
AS in the menu bar under PROJECT.
2. Enter a file name in the dialog window and confirm it via SAVE.
The SOPAS-ET configuration software saves the current settings in a configuration
file “*.SPR“.
3. In order to print out the current parameter set, select the command PRINT/PRINT
PREVIEW in the menu bar under PROJECT.
The SOPAS-ET configuration software displays a preview of a table with a list of
all the parameter values.
4. Click on in the tool bar at the top of the dialog window.
The dialog window PRINT for the printer configuration appears.
5. Edit setting accordingly and confirm with OK.
The current project settings are printed as a table on several pages.
6.5 Default settings
The values of the default setting are permanently saved in the bar code scanner (ROM)
and in the database of the SOPAS-ET configuration software in the device-specific jar
file (see chapter “First startup”). A PC is not required to start up the RFH620 with the
default setting.
6.5.1 Resetting the default setting in the RFH620
The SOPAS-ET configuration software is connected online to the RFH620. Two default
setting types can be called up via the SOPAS-ET configuration software:
¾
Complete default setting (LOAD FACTORY DEFAULT)
SOPAS-ET resets all parameter values of the RFH620 to default. Settings which
have been previously made for the communication parameters of the Ethernet