3.2.3
Compatible sensor types
The safety relay is suitable for:
•
Safety sensors and safety switches with OSSD output, e.g.: Electro-sensitive pro‐
tective equipment (ESPE) with a single-channel or dual-channel monitored active
switching output with cross-circuit detection (OSSD)
3.2.4
Restart interlock
A restart interlock can be implemented with a reset pushbutton.
3.2.5
External device monitoring
Permanent external device monitoring can be implemented using external wiring.
3.2.6
Status indicators
LEDs
PWR
OUT
13
23
I1
Y1
14
24
I2
Y2
A2
R
E
L
Y
R1
A1
S1
OSSD2
1085344
PWR
OUT
13
23
I1
Y1
14
24
I2
Y2
A2
R
E
L
Y
S1
R1
A1
Figure 2: LEDs
The labeled positions are only partially assigned LEDs. The positions and their labeling
(except for the upper 2 lines) also show the pin assignment of the terminals on the front
connector.
Table 1: Safety relay indicators
Labeling
Color
Function
PWR
Green/Red
Voltage supply
OUT
Green
Enabling current paths
I1
Green
Safety capable input
I2
Green
Safety capable input
S1
Green
Reset pushbutton input, exter‐
nal device monitoring (EDM)
Y1
Green
Application diagnostic output
Y2
Green
Application diagnostic output
(reset required)
Further topics
•
"Status indicator (LED)", page 23
3
PRODUCT DESCRIPTION
10
O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD2
8020864/15W3/2020-02-21 | SICK
Subject to change without notice