Operating Instructions
PBS
32
© SICK AG • Germany • All rights reserved • Subject to change without notice
8013154/U275/2010/02/01
Specifications
Model PBS
Internal transmission fluid
Synthetic Oil
(only for pressure ranges < 0 ... 10 bar and
≤
0 ... 25 bar abs)
Power supply L+
L+ in V DC
15 ... 35
Signal output and
R
A
in Ohm
4 ... 20 mA, 3-wire
R
A
≤
0,5 k
maximum ohmic load R
A
0 …10 V, 3-wire
R
A
>
10 k
Adjustment zero point offset, max. 3 % of span
Setting time (Analogue signal)
ms
3
Current consumption
mA
max. 100
Total current consumption
mA
max. 600 (max. 500 with IO-Link) incl. switching current
Switch points
Individually adjustable via external control keys
Type
Transistor switching output PNP or NPN, with IO-Link: C/Q1: PNP
Number
1 or 2
Function
normally open / normally closed;
windows- and hysteresis function freely
adjustable
Contact rating
V DC
Supply voltage L+ - 1 V
Switching current
mA
Q1: 250 (with IO-Link: C/Q1: 100), Q2: 250
Response time
ms
≤
10
Accuracy
% of span
≤
0.5 (setting accuracy)
Insulationvoltage
V DC
500
Display
Design
14-Segment-LED, blue 4-digits, height 9 mm
Range
Electronic 180° rotatable
Accuracy
% of span
≤
1.0 ± 1 Digit
Update
ms
1000, 500, 200, 100 (adjustable)
Accuracy
% of span
≤
1.0 *
)
*
)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2)
Non-linearity
% of span
≤
± 0.5
(BFSL) according to IEC 61298-2
7. Starting, operation