ã
Detection area
e
Measuring range
10.4
Performance
Scan/frame rate
55000 … 165000 measuring points/second
Response time
typically 20 ms (4 layers), typically 80 ms (1 layer)
min. 7 ms, max. 84 ms + 1 scan
Systematic error
± 60 mm
Temperature drift: Typically ± 0.5 mm/K
Statistical error
≤ 30 mm
Integrated application
Integrated field evaluation with flexible fields on 4 levels, data
output
Number of field sets
Up to 64 fields
Simultaneous analysis
cases
Up to 16 analyses
Filters
Fog filter, particle filter, average filter, median filter, ground refer‐
ence evaluation, edge filter, echo filter
1)
Depends on the object size and selected filter settings.
10.5
Interfaces
Ethernet
✓
, TCP/ IP, UDP/ IP
Function: HOST, OPC, NTP
Measured data output (distance, RSSI)
Data transmission rate: 10/100 Mbit/s
digital inputs/outputs
I/O (8 (multiport))
Output data
Contamination indication, IMU (secondary sensor data)
Optical indicators
2 LEDs
Configuration software
SOPAS ET, web server (display)
10.6
Ambient data
Object remission
2% ... > 1,000% (reflector)
Electromagnetic compati‐
bility (EMC)
EN 61000-6-2:2005
EN 61000-6-3:2007+A1:2011
Vibration resistance
EN 60068-2-6:2007
Shock resistance
EN 60068-2-27:2008
Ambient operating temper‐
ature
MRSxxxx-0xxxxx: -10 °C … +50 °C
MRSxxxx-1xxxxx: -30 °C … +50 °C
Storage temperature
-40 °C … +75 °C
Operating and storage air
humidity
Max 90% air humidity (non-condensing)
Ambient light immunity
80 klx
TECHNICAL DATA
10
8020494/1AZF/2021-05-10 | SICK
O P E R A T I N G I N S T R U C T I O N S | MRS1000
55
Subject to change without notice