D
H
≈
0 mm
C
=
1200 mm
Figure 20: Protection against reaching over when mounted low (dimensions in mm)
D
H
=
875 mm
C
=
850 mm
Figure 21: Protection against reaching over when mounted high (dimensions in mm)
The necessary supplement to the minimum distance depends on the height of the
protective field’s scan plane. The supplement is larger if the safety laser scanner is
affixed low-down than if it is affixed high-up.
Calculating the supplement C
b
If you have sufficient free space in front of your machine, use value 1200
mm as
the supplement C.
b
If you want to keep the minimum distance as low as possible, use the following
formula to calculate C:
C = 1200 mm – (0.4 × H
D
)
where:
°
H
D
= height of the protective field above the floor in millimeters (mm).
PROJECT PLANNING
4
8017784/1ELL/2022-01-21 | SICK