3
Product description
3.1
Product identification
Type code
Table 2: Type code
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
M
T
X
4
8
N
-
1
1
R
1
0
T
T
Table 3: Type code Explanation
Position
Meaning
Value
1
Series
M = Mobile
2
Technology
A = Magnetostrictive
3
Installation type
X = Integrated (hydraulic cylinder)
4
Size
48 = Housing diameter
5
6
Version
N = Non-Safety
7
Place holder
-
8
Diameter
Pressure pipe
1 = 10 mm / 30 mm damping
7 = 7 mm / 30 mm damping
9
Voltage supply
1 = 12 VDC
2 = 24 VDC
10
Electrical
Interface
V = Voltage
A = Current
11
Signal output
10 = Analog 4.00 ... 20.00 VDC
21 = Analog 4.75 ... 0.25 VDC
40 = Analog 1.00 ... 9.00 VDC
12
13
Connection type
A = 4-pin analog (1 = VDC, 2 = n.c., 3 = GND, 4 = OUT)
B = 4-pin analog (1 = VDC, 2 = OUT, 3 = GND, 4 = n.c.)
M = 4-pin analog (1 = n.c., 2 = VDC, 3 = GND, 4 = OUT)
K = Analog cable/3-wire PWM
14
Connector length
A = 60 mm M12
E = 100 mm M12
15
Measuring range
Position measurement
in 1 mm steps
e.g., 0300 = 50 ... 300 mm
16
17
18
3.2
Device variants
The device is available in the following variants:
•
M12 male connector (4-pin) or 3-wire PUR cable
3
PRODUCT DESCRIPTION
8
T E C H N I C A L I N F O R M A T I O N | MAX48
8021473/2017-08-08 | SICK
Subject to change without notice