3
Maintenance
3.1
Maintenance plan
NOTICE
This Maintenance plan describes the maintenance work specified by the manufacturer.
Inspections according to guidelines to be applied by the operator (e.g. MARPOL Annex
VI) shall be carried out according to the intervals described therein.
NOTE
Spare parts list:
see "Consumable, wearing and spare parts", page 13
Table 3: Maintenance intervals
Interval
1)
Maintenance work
Remark
1 W
Check pending messages (control unit).
See Operating Instructions, Section
12.1
Check the system
See Operating Instructions, Section
8.3
Gas sampling unit
•
Check the gas sampling filter by checking the gas
flow on the analyzer display.
•
Replace the gas sampling filter if the gas flow
shown in measuring mode <120 l/h.
See Operating Instructions, Section
8.6
1 M
Analyzer cabinet
•
Check the filter pads.
•
Clean or replace the filter pads as necessary.
See Operating Instructions, Section
8.5
•
Check the exhaust hose to see if blocked or
kinked.
•
Clean or replace the exhaust hose as necessary.
See Operating Instructions, Section
3.3.4, Fig. 5, position
8
See Operating Instructions, Section
8.1.2
3 M
Conditioning of instrument air:
Option FRL-SF0025 without using pre-filter
•
Replace carbon filter.
See Operating Instructions, Section
8.4
6 M
Gas sampling unit
•
Replace the gas sampling filter. <120 l/h.
See Operating Instructions, Section
8.6
Electronics module
•
Replace the filter pad.
see "Replacing the Electronics module
filter pad", page 11
Perform a leak tightness check.
See Operating Instructions, Section
8.12
MAINTENANCE
3
8026470/AE00/V1-0/2021-04 | SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | MARSIC300
7