Mounting
40
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
8013796/UL20/2010-09-27
Operating Instructions
Laser Measurement Systems of the LMS500 Product Family
Chapter
4
4.3
Mounting steps
Special features to note during mounting:
•
Mount the LMS such that it is protected from moisture, dirt, damage and direct sunlight.
•
Ensure that the entire field of view of the LMS is not restricted.
•
Mount the laser measurement system such that the indicators are easy to see.
•
Always mount the LMS so that there is still enough space for mounting and removing
the system plug.
•
Avoid excessive shock and vibration loading on the laser measurement system.
•
On applications that suffer from heavy vibration, prevent the fixing screws from coming
loose using screw locking devices (see
section 9.1 “Data sheet LMS laser
measurement system” on page 67
).
•
Regularly check the tightness of the fixing screws.
•
Pay attention to the maximum torque for the fixing screws on the LMS:
– M6 on rear = max. 12 Nm
– M8 on side = max. 16 Nm
The LMS can be fastened in the following ways:
•
direct mounting without mounting kit
•
mounting with mounting kit 1
•
mounting with mounting kit 2 (only in conjunction with mounting kit 1)
•
mounting with mounting kit 3 (only in conjunction with mounting kits 1 and 2)
4.3.1
Direct mounting
The LMS has four M6×8 threaded holes on the rear. Using them you can mount the LMS
directly on the intended mounting surface.
Fig. 22:
Direct mounting
M6×8