Chapter
4
Operating Instructions
Laser measurement sensor LD-MRS
56
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8012948/ZMQ0/2017-06-09
Mounting
4
Mounting
This chapter describes the mounting steps for the LD-MRS.
4.1
Overview of the mounting steps
The following list gives an overview of the typical mounting steps:
•
select a mounting location for the LD-MRS
•
mount and adjust the LD-MRS
4.2
Preparations for mounting
In general, observe the following requirements for mounting:
•
mounting location with free view of the scanning range of the LD-MRS, see
Chapter 9.2.4 Holder (optional accessory), Page 100
.
•
stable mounting support with sufficient bearing capacity and suitable dimensions for
LD-MRS
•
if needed behind a pane (glass or acrylic glass) which is transparent for infrared light
(905 nm). For more detailed information about suitable material contact SICK AG.
The following accessories are required for mounting:
•
4 M6 screws of property class 8.8 to attach the LD-MRS at the mounting support. The
length of the screws depends on the wall thickness of the support.
•
Tools
4.2.1
Prepare the components to be mounted
•
Laser measurement sensor LD-MRS
•
Optional: Mounting bracket for adjustable alignment of the LD-MRS
•
In addition for field monitoring:
– depending on the number of employed logical switching outputs and inputs, one or
two optional CAN modules for installation in the system (box) or the switching cabi-
net on a top hat rail (snap)
– When using only one CAN module, the connector (Part No. 6042511) with integrat-
ed termination resistance
4.2.2
Mounting device
The LD-MRS is attached by means of the 4 holes located in the four projecting attachment
lugs at the rear side of the device.
To make it easier to align the LD-MRS and protect from external influences, SICK AG offers
the following optional accessories:
•
Holder Part No. 1047429 (adjustable in 2 axes)
•
Weather resistant cover Part No. 2058033