Operating Instructions
Chapter
2
LD-MRS
For your safety
8012948/ZMQ0/2017-06-09
©
SICK AG · Germany · All rights reserved · Subject to change without notice
13
2.4.2
Electrical installation tasks
•
Only trained personnel may perform the electrical installation.
•
Electrical connection may only be established or disconnected when not under voltage.
•
Specify and implement the wire diameter and the correct fusing according to valid stan-
dards.
2.4.3
Malfunctions
CAN modules for external switching inputs and outputs (accessories)
NOTICE
Potential radio interference when using the optional CAN modules in residential areas.
Only use the laser measurement sensor LD-MRS together with the CAN modules in an
industrial setting.
2.4.4
Laser protection
CAUTION
Laser radiation!
The LD-MRS uses infrared light laser. The device is specified as laser class 1 (eye-safe).
The laser beam is invisible to the human eye!
Caution — use of controls, adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
Do not open the housing of the LD-MRS (opening the housing does not interrupt laser
operation).
Observe the valid laser protection regulations in their newest version.
Laser power
The laser operates at a wave length
λ
= approx. 905 nm (invisible infrared light).
The product is classified as laser class 1 EN
/IEC
60825-1
:2014
, 21 CFR 1040.10 and 21
CFR 1040.11.
Identical laser class for issue EN/IEC 60825-1:2007.
The radiation emitted
in normal operation is not harm-ful to the eyes and human skin.
Important
In order to ensure laser class 1, no maintenance is necessary.
Laser output aperture
The laser output aperture is the window of the LD-MRS.